Back to search

University of British Columbia

Gas transport and water vapourization in out-of-autoclave prepreg laminates

Abstract

dc:description

Primary load-bearing aerospace structures have traditionally been manufactured using autoclave processing. However, recent advances in material technology have led to the development of pre-impregnated (prepreg) composites that are designed to be cured out-of-autoclave (OOA) and can potentially reduce the costs of processing. In OOA processing, voids are removed by vacuum evacuation through gas pathways in the prepreg. The availability and interconnectivity of these pathways determine the prepreg’s gas transport ability. Voids enter into the prepreg via moisture absorption during storage and physical air entrapment during manufacturing and material handling. Environmental effects, such as relative humidity, can alter the moisture content of prepregs and lead to significant vapour generation during cure. This study examines the gas transport and water vapourization characteristics of OOA prepreg CYCOM 5320/T650 (epoxy/carbon). Gas permeabilities in the in-plane and through-thickness directions are measured, and the effects of processing history (debulk time, temperature etc.) on gas transport are examined. The relationships between relative humidity, moisture content, and vapour generation are analyzed, and the use of mass flow sensors for water vapour quantification is validated. Gas transport is shown to be highly anisotropic in CYCOM 5320/T650, with inplane gas permeability being three orders of magnitude greater than through thickness. Processing history has a significant effect on permeability, with extended debulking sessions reducing in-plane permeability by 50%. Increasing temperature causes in-plane and through-thickness permeabilities to fall. Microscopy analyses reveal that permeability change is a result of collapsing voids and resin flow during heating. Moisture content is relatively unaffected by relative humidity until reaching 30% RH, after which increases in moisture content become more apparent. Vapourization of absorbed moisture between 0 %RH and ambient conditioned vacuum bagged laminates are similar, suggesting that under typical process conditions moisture vapourization mainly comes from the vacuum bag consumables. During vacuum bag processing, vapourization of absorbed moisture occurs immediately upon heating, peaks around 40 to 60oC, and then dissipates as heating reaches the hold temperature. The mass flow sensors are demonstrated to be capable of detecting the onset and termination of moisture vapourization and quantifying the total mass of water vapourized to within 10% error.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Materials Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hsiao, Kevin

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/42610

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Hsiao, Kevin. Gas transport and water vapourization in out-of-autoclave prepreg laminates. master's thesis, University of British Columbia, 2012. http://hdl.handle.net/2429/42610