Back to search

University of British Columbia

Change in patient-reported outcomes after cardioverter-defibrillator implantation

Abstract

dc:description

Some people, because they have a genetic predisposition or heart disease, are at high risk for cardiac arrhythmias that could cause their hearts to stop. The implantable cardioverter-defibrillator (ICD) is an effective therapy that recognises abnormal heart beats, can administer an electrical shock to stop a potentially lethal heart rhythm, and affords protection from the devastating consequences of sudden cardiac arrest. Patient-reported outcomes (PROs) are assessments provided directly by patients about various aspects of their health and quality of life. We sought to study the change in PROs after ICD implantation to identify people’s patterns of change, explore individual trajectories of change, and identify predictors of differences in individuals’ trajectories. The study was grounded in the Wilson and Cleary (1995) conceptual framework of quality of life and informed by the Patient-Reported Outcomes Measurement Information System domain framework. Using a prospective, longitudinal study design, data were obtained from 171 people undergoing ICD implantation at quaternary centres in British Columbia, Canada (55.5% response rate). PRO assessments were obtained immediately before implantation and at one, two, and six months following implantation. We employed individual growth modelling to analyse change within and between people. The participants had different physical, mental, and social health status PROs at baseline and, on average, demonstrated improvement. At most of the measurement occasions, the participants’ PROs remained poorer than those of average adult, urban-dwelling Canadians. There was significant individual variability in most of the trajectories, especially in the social functioning domains. Relative to men, women reported worse PROs initially (the relative mean difference in men’s and women’s scores ranged from 4.5% to 24.7% for 6 of the 12 indicators). Yet, the women’s rates of improvement were significantly faster than those of men. Women equalled or exceeded the men’s PROs at the six-month assessment (the relative mean difference ranged from 4.5% to 10.4%, depending on the PRO). Further research is needed to explore the individual change trajectories identified in this study, especially for those patients who did not improve over time, fully test the conceptual model that framed the research, and evaluate interventions aimed at improving PROs after ICD implantation.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Nursing
Grantor dc:publisher
University of British Columbia
Year dc:date
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lauck, Sandra Béatrice

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/43914

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Lauck, Sandra Béatrice. Change in patient-reported outcomes after cardioverter-defibrillator implantation. doctoral thesis, University of British Columbia, 2013. http://hdl.handle.net/2429/43914