Back to search

University of British Columbia

Comparison of proximal femur deformations, failures and fractures in quasi-static and inertially-driven simulations of a sideways fall from standing : an experimental study utilizing novel fall simulation, digital image correlation, and development of digital volume correlation techniques

Abstract

dc:description

Knowledge of proximal femur failure mechanics has a pivotal role to play in predicting who might suffer a hip fracture. Previous researchers of sideways falls resulting in hip fracture have investigated the roles of several bone parameters such as bone mineral density and morphology, as well as different modelling boundary conditions. While important advances have been made, current models use constant displacement rates applied at the greater trochanter, which may not allow the bone to respond as it would in a sideways fall. Proximal femurs have been shown to be sensitive to displacement rate, but impacts like those in a sideways falls have never been examined. The goal of this thesis was to compare the results of constant displacement rate testing to more biofidelic, inertially driven, impact fall simulation testing and determine how these methods influence specific test outcomes. In study 1, sub-failure loads were applied to single bones at constant displacement rate, followed by impact loading in the fall simulator. Stiffnesses, energies and strains at a point were compared. In study 2, the same bones were compared using digital image correlation to examine bone strains on the anterior-superior femoral neck. In study 3, two cohorts of bones were loaded to failure, one at constant displacement rate and the other in the impact fall simulator. Initial failure locations, fracture patterns, stiffnesses and energies to failure were compared. The results of study 1 indicate that the behaviours of the bones were not affected by the change in loading. In study 2, I found that individual specimen strain maps were sensitive to the change in loading parameters; however, pooling the data from all the specimens yielded no statistical difference. In study 3, I discovered that final fracture patterns were different, but initial failure locations, stiffnesses and energies to fracture were not. Additionally, femurs tested in the fall simulator did not show significant viscoelasticity. These data indicate that sub-failure measures of mechanical bone behaviour are insensitive to changing between constant displacement rate and impact fall simulation testing; however, strain pattern and final fracture behaviours are influence by changing the loading protocol.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gilchrist, Seth Myles

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivs 2.5 Canada
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/46284

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Gilchrist, Seth Myles. Comparison of proximal femur deformations, failures and fractures in quasi-static and inertially-driven simulations of a sideways fall from standing : an experimental study utilizing novel fall simulation, digital image correlation, and development of digital volume correlation techniques. doctoral thesis, University of British Columbia, 2014. http://hdl.handle.net/2429/46284