Back to search

University of British Columbia

Optical resonator sensors and systems

Abstract

dc:description

Silicon-on-insulator (SOI)-based sensors are attractive for sensing applications in environmental safety, oil and gas, medical research, and clinical applications. Since these devices are typically developed using Complementary metal-oxide-semiconductor (CMOS)-compatible multi-project-wafer (MPW) shuttles, they bring the potential for having sensing systems on chips (SSOCs), and for mass fabrication and low cost production. The objective of this thesis is to improve the sensitivity, accuracy, and repeatability of sensors fabricated on the SOI platform. Such sensors have the potential to be the key components of an SSOC. One can increase the sensitivity of a resonator sensor by increasing the interaction between the evanescent field of the guided mode and the analyte. In this thesis, two methods for increasing this interaction in micro-ring resonator-based sensors are investigated: 1) using the transverse electric (TE) guided mode in ultra-thin strip waveguides and 2) using the quasi-transverse magnetic (TM) guided mode in thin strip waveguides. Using analyses and simulations, micro-ring sensors were designed to be fabricated within the constraints of a MPW CMOS-compatible process. Using the TE sensors, the temperature-induced errors were reduced by a factor of three; and the TM sensors exhibited twice the sensitivity of the best SOI micro-ring resonator-based sensors reported to date. Moving towards the actual implementation of an SSOC, a system of sensors was design to correct for unwanted variations in the measurements. This system drew on multivariate techniques to achieve improvements that resulted in measurements that were more repeatable and more accurate in the presence of environmental variations. The capability of this system is investigated by designing a cascade of previously developed micro-ring sensors with various waveguide thicknesses. With this system of sensors, we achieved an R2 value of predictions over 0.996 in the presence of a 2 K temperature drift. This approach significantly improved the repeatability and reliability of the measurements in the presence of undesirable variations and drifts. In another move towards achieving an SSOC, integrating photodetectors in resonator sensors was investigated. To accomplish this, ion-implantation on micro-ring sensors was used. Such integrated photodetector-sensors were designed, fabricated, and tested. Their measured sensitivities were within 90% of the expected values.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Talebi Fard, Sahba

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivs 2.5 Canada
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/52834

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Talebi Fard, Sahba. Optical resonator sensors and systems. doctoral thesis, University of British Columbia, 2015. http://hdl.handle.net/2429/52834