Back to search

University of British Columbia

Assessment of stiffness in intact cartilage using contrast-enhanced computed tomography (CECT)

Abstract

dc:description

Introduction: Osteoarthritis (OA) is the most prevalent joint disease in Canada, affecting millions of people. OA begins with softening of cartilage and is characterized by progressive loss of the tissue resulting in joint impairment. Because cartilage’s primary function is mechanical, and because OA disrupts cartilage’s mechanical function, there is a substantial need for a non-invasive method to assess cartilage mechanics. Contrast-enhanced computed tomography (CECT) using charged contrast agents is an imaging method developed to quantify Glycosaminoglycan (GAG) content of cartilage. Since GAG is a key determinant of cartilage compressive stiffness, CECT measurements may be correlated with cartilage stiffness. The objective of this study was to determine whether CECT using a novel cationic contrast agent (CA4+) is correlated with cartilage stiffness in intact human joint surfaces. Methods: Six human femoral condyle compartments with intact healthy cartilage (ICRS grade 0 or 1) were used. Cartilage stiffness was measured across the surface in a Mach-1 testing system (Biomomentum, Montreal) using an indentation test. The samples were then immersed in CA4+ solution for 48 hours and then scanned at 41μm resolution in a hr-pQCT scanner (Xtreme CT, Scanco, Zurich). The averages of CECT attenuations at the sites of the indentation tests were computed for both superficial cartilage (600μm depth) and for the full thickness of cartilage. Correlations between stiffness and CECT attenuation were assessed with scatter plots and Pearson’s correlation coefficient. Results: A significant and positive correlation was observed between stiffness data and mean CECT attenuations in superficial cartilage across all samples, with correlation coefficients ranging from r=0.4 to 0.72, and p<0.01. When data from all locations were pooled (n=221), the correlation coefficient was r=0.55 and a regression line fitted to the data predicted stiffness from CECT measurements with an error of 20% of the stiffness range. However, correlations between stiffness and CECT attenuations in full-depth cartilage were substantially lower and not significant in half of the tested specimens. CECT identified regions of reduced cartilage stiffness and the expected depth dependent changes in GAG concentration. Conclusion: CECT of superficial cartilage using CA4+ provides a surrogate measure of compressive cartilage stiffness in intact joint surfaces.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Nickmanesh, Reza

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivs 2.5 Canada
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/54580

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Nickmanesh, Reza. Assessment of stiffness in intact cartilage using contrast-enhanced computed tomography (CECT). master's thesis, University of British Columbia, 2015. http://hdl.handle.net/2429/54580