Development of a computer-controlled device to quantitatively measure the degree of spasticity at a subject’s ankle

Abstract

dc:description

The objective of this thesis project was to develop a device to quantitatively measure the degree of spasticity at a subject's ankle, and to use this device to find a means to determine a quantified measure of spasticity. The device imposes a controlled passive rotation of a subject's ankle joint, while simultaneously recording the resulting resistive torque and associated electromyographic (EMG) muscle activity. Comparative analysis of Data from subjects with and without spasticity were compared to identify response characteristics and parameters which could be associated with the presence and/or severity of spasticity. These differences were evaluated by modeling the data with a mathematical equation representing spasticity response. Parameters of the equation were then analyzed, and two of the four parameters deemed to be robust, reliable indicators of spasticity, were plotted to create a diagnostic model and curve for distinguishing between test subjects with and without spasticity. The perpendicular distance of the data points from the model curve can then be utilized as a quantified measure of spasticity. This quantified measure of spasticity was found to correlate with clinical evaluations. The analysis of variance test determined a 7.8 % probability that the sets of data, from subjects with and without spasticity, were from the same population, indicating that there was a significant difference between the two data sets. Thus it is concluded that a diagnostic model has been developed which shows potential as a means to quantify spasticity.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
1996

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Aitchison, Jeffrey R.

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/5720

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Aitchison, Jeffrey R.. Development of a computer-controlled device to quantitatively measure the degree of spasticity at a subject’s ankle. master's thesis, University of British Columbia, 1996. http://hdl.handle.net/2429/5720