Transmission dosimetry with a scanning liquid filled electronic portal imaging device for megavoltage photo beams

Abstract

dc:description

An important question with respect to radiation therapy is to what degree of accuracy, dose delivery can be achieved in clinical practice. It is well understood that accurate delivery of a specific radiation dose to a target volume is critical to the success of radiation therapy. The use of portal imaging in radiotherapy for verification of field size, shape, orientation and patient setup is of vital importance in delivering successful radiation treatment. One of the modalities used in improving tumor localization and geometric verification of field sizes is the on-line electronic portal imaging device (EPID). In this thesis, the dosimetric characteristics of a scanning liquid - filled ionization chamber electronic portal imaging device (SLIC-EPID) have been investigated. To assess the system's response in relation to radiation beam intensity, a series of characteristic curves were obtained for various field sizes and energies. It was shown that the response of the imaging system was dependent on incident radiation intensity and could be characterized by a square root function to within 1% accuracy. Exit dose measurements with the SLIC - EPID on the central axis of the beam using homogeneous attenuating phantom materials revealed that the Portal Vision™ is capable of measuring the transmission dose to within 3% of standard dosimeters, such as the ionization chamber. For dosimetry applications, additional build-up material on top of the detector cassette of the portal imager is required to calibrate the system prior to dose measurements. Open field and wedged dose profiles of the portal imager show an accuracy of better than 3.5% when compared with those obtained using an ionization chamber in regions near field edges. SLIC-EPIDs, when configured appropriately have the potential of being used as exit dosimeters. They are capable of determining the relative dose at the exit surface of the patient with an accuracy of better than 3.5%.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
1997

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Parsaei, Homayoon

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/5838

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Parsaei, Homayoon. Transmission dosimetry with a scanning liquid filled electronic portal imaging device for megavoltage photo beams. master's thesis, University of British Columbia, 1997. http://hdl.handle.net/2429/5838