Back to search

University of British Columbia

Dual mode brain near infrared spectroscopy and electroencephalography hardware design and signal processing

Abstract

dc:description

Electroencephalography (EEG) and cerebral near-infrared spectroscopy (NIRS) are both well-known monitoring methods for analyzing cerebral neurophysiology and hemodynamics. Neuronal activity in the gray matter of the brain requires energy and thus a high metabolic rate, which is related to oxygen consumption. The blood regulatory system operates to ensure sufficient spatial and temporal distribution of oxygen and energy substrates to supply neuronal activity. In this study, we designed and developed a prototype NIRS/EEG instrument for recording electrophysiological activity and hemodynamic changes in the human forehead. This novel probe, combining both EEG and NIRS technologies, consists of Ag/AgCl EEG electrodes positioned between NIRS optodes. As ambient light is capable of contaminating the NIRS signal, a novel amplitude modulation methodology was incorporated into the NIRS/EEG device for multiplexing NIRS light sources and eliminating the interfering noise signal produced by ambient light. This method is based on the modulation of each specific NIR source by its specific carrier frequency. The summation of all sources and ambient interference is measured at the receiver site. A bandpass filter separates each source based on the carrier frequency. Three experiments were conducted using the aforementioned NIRS/EEG instrument. The experiments were performed on five healthy human subjects. The initial experiment was conducted to evaluate the functionality of the developed NIRS/EEG prototype. The association between gamma-band oscillations and total hemoglobin during subjective pain (Cold Pressor Test, CPT) was demonstrated. The increase in gamma-band oscillations, as measured by EEG electrodes on the forehead, and the increase of total hemoglobin, as measured by NIRS optodes on the forehead, have been recorded and reported accordingly. Conventional EEG recording is conducted in the 0.16 to 70 Hz frequency range. However, ultra-low-frequency EEG, found in the range of 0.015 to 4 Hz, is highly informative and allows discovery of the general state of neurons. The genesis of low-frequency EEG signals may be non-neuronal. In the last experiment, the changes of pCO₂ and low-frequency EEG are measured concurrently and the results are presented accordingly.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Shahbaz, Askari

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/58418

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Shahbaz, Askari. Dual mode brain near infrared spectroscopy and electroencephalography hardware design and signal processing. master's thesis, University of British Columbia, 2016. http://hdl.handle.net/2429/58418