Back to search

University of British Columbia

Assessment of type II diabetes mellitus

Abstract

dc:description

Several methods have been proposed to evaluate a person's insulin sensitivity (ISI). However, all are neither easy nor inexpensive to implement. Therefore, the purpose of this research is to develop a new ISI that can be easily and accurately obtained by patients themselves without costly, time consuming and inconvenient testing methods. In this thesis, the proposed testing method has been simulated on the computerized model of the type II diabetic-patients to estimate the ISI. The proposed new ISI correlates well with the ISI called M-value obtained from the gold standard but elaborate euglycemic hyperinsulinemic clamp (r = 0.927, p = 0.0045). In this research, using a stochastic nonlinear state-space model, the insulin-glucose dynamics in type II diabetes mellitus is modeled. If only a few blood glucose and insulin measurements per day are available in a non-clinical setting, estimating the parameters of such a model is difficult. Therefore, when the glucose and insulin concentrations are only available at irregular intervals, developing a predictive model of the blood glucose of a person with type II diabetes mellitus is important. To overcome these difficulties, under various levels of randomly missing clinical data, we resort to online Sequential Monte Carlo estimation of states and parameters of the state-space model for type II diabetic patients. This method is efficient in monitoring and estimating the dynamics of the peripheral glucose, insulin and incretins concentration when 10%, 25% and 50% of the simulated clinical data were randomly removed. Variabilities such as insulin sensitivity, carbohydrates intake, exercise, and more make controlling blood glucose level a complex problem. In patients with advanced TIIDM, the control of blood glucose level may fail even under insulin pump therapy. Therefore, building a reliable model-based fault detection (FD) system to detect failures in controlling blood glucose level is critical. In this thesis, we propose utilizing a validated robust model-based FD technique for detecting faults in the insulin infusion system and detecting patients organ dysfunction. Our results show that the proposed technique is capable of detecting disconnection in insulin infusion systems and detecting peripheral and hepatic insulin resistance.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Chemical and Biological Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Barazandegan, Melissa

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/59826

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Barazandegan, Melissa. Assessment of type II diabetes mellitus. doctoral thesis, University of British Columbia, 2016. http://hdl.handle.net/2429/59826