Back to search

University of British Columbia

Skin mechanics, intradermal delivery and biosensing with hollow metallic microneedles

Abstract

dc:description

Microneedles (MNs) have gained significant attention over the past decade in drug delivery and biosensing due to their minimally-invasive and less painful nature of use compared to intramuscular/subcutaneous injections, and significant biological benefits. Several fundamental processes enabling MN functionality have not been completely understood, including mechanical interaction between MNs and skin for targeted depth penetration; and precise quantification of fluid delivery in the skin. This thesis presents novel materials, and methodologies for evaluating MN interactions with skin, and investigates the performance of hollow MNs in both intradermal fluid drug delivery and biosensing. A micromechanical comparison between human skin and porcine skin was performed using to determine their mechanical behavior affecting MN insertions. Stratum corneum (SC) of human skin was significantly stiffer (117 ± 42 MPa) than porcine skin (81 ± 32 MPa), requiring higher force of MN insertion to rupture the SC in human skin (107 ± 17 mN) than porcine skin (96 ± 23 mN). An artificial mechanical skin model was developed layer-by-layer to simulate tough human skin (MN insertion force 162 ± 11 mN) and to study the dynamics of MN insertion. Key factors that affected MN insertions into skin, including velocity of impact and total energy delivered to the skin, were identified. ID fluid delivery by hollow MNs was assessed using a novel method involving the low-activity radiotracer technetium-99m pertechnetate (⁹⁹mTcO₄₋). Its delivery allowed accurate quantification of fluid delivered into the skin, back-flowed to the skin surface, and total fluid ejected from the syringes via ID devices with sub-nanoliter resolution. Hollow MNs performed more accurate ID injections than conventional needles (93% vs. 69-87% of fluid per 0.1 mL injection volume). A MN-optofluidic biosensing platform capable of eliminating blood sampling was developed with MNs that can access dermal interstitial fluid that contains numerous drugs at concentrations comparable to blood. The MN lumen was functionalized to collect, trap and detect drugs in 0.6 nL of sample. The optofluidic components provided specific high-sensitivity absorbance measurements for drug binding using enzyme-linked assays. Streptavidin-horseradish peroxidase (LoD = 60.2 nM) and vancomycin (LoD = 84 nM) binding validated this point of care system.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ranamukhaarachchi, Sahan

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/61168

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Ranamukhaarachchi, Sahan. Skin mechanics, intradermal delivery and biosensing with hollow metallic microneedles. doctoral thesis, University of British Columbia, 2017. http://hdl.handle.net/2429/61168