Back to search

University of British Columbia

In vitro evaluation of the effects of leukocyte-platelet rich fibrin on disinfection of a rough implant surface

Abstract

dc:description

Objectives: Peri-implantitis is a frequent and serious clinical problem affecting between 1 and 47% of implants. Bacterial contamination of the roughened implant surface plays a major role in the etiology and progression of the disease. Successful treatment of peri-implantitis requires disinfection of the rough implant surface. There is no generally accepted protocol for implant disinfection. Autologous leukocyte and platelet-rich fibrin (L-PRF) membranes can be produced from autologous human blood via a one-step centrifugation procedure. It was hypothesized that the antimicrobial defense system of L-PRF may decontaminate the SLAⓇ implant surface. The objective of this study was to test the efficacy of L-PRF for SLAⓇ implant surface disinfection. Methods: Collagen-coated SLAⓇ (sand blasted, large grit acid etched) titanium discs were inoculated with dispersed dental plaque with a minimum bacterial cell concentration of 3.2 × 10⁷ CFU/ml. After 21 days of anaerobic incubation at 37C, discs were rinsed with 12 ml 0.9% NaCl to remove unattached biofilm, and exposed for 48 hours to Leukocyte-Platelet Rich Fibrin (L-PRF) in DMEM. Disks with or without rinsing with 12 ml of 0.9 % NaCl were fixed for SEM. Bacterial counts and perforations in bacteria were quantified from standardized scanning electron micrographs of the implant surface. The rinsing solution was collected and Western blot analysis was performed. L-PRF disks were compared with the control group (rinse). Results: Difference in presence of bacteria displaying perforation of the cell wall between cell–rich L-PRF treated samples and rinsed control group was statistically significant (p < 0.0001, Fisher's Exact Test). Western blot analysis of the rinse fluid demonstrated presence of Platelet Factor-4. Activated platelets in intimate contact with bacteria were detected on SEM images. SEM analysis demonstrated a statistically significant reduction of residual bacteria in the lacunae of the rough SLAⓇ surface after L-PRF treatment. (p< 0.05, Kruskal-Wallis). Conclusions: Autologous L-PRF may have potential as a biological means to decontaminate rough implant surfaces, possibly by exploiting the antimicrobial effects of platelets.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Craniofacial Science
Grantor dc:publisher
University of British Columbia
Year dc:date
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Schuldt, Luisa Antonia

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/62613

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Schuldt, Luisa Antonia. In vitro evaluation of the effects of leukocyte-platelet rich fibrin on disinfection of a rough implant surface. master's thesis, University of British Columbia, 2017. http://hdl.handle.net/2429/62613