Back to search

University of British Columbia

Local pulse wave velocity detection over an arterial segment using photoplethysmography

Abstract

dc:description

The goal of this thesis is to determine the validity of using photoplethysmography (the detection of changes of blood volume using light) to measure pulse wave velocity as part of a continuous and non-disruptive blood pressure monitor. There has been a limited advancement over the years in technologies to monitor personal blood pressure, which have rendered at-home monitoring still relatively intrusive. The main method for at-home blood pressure monitoring is the use of an inflating cuff that obstructs the artery to detect pressure. This system suffers from inherit drawbacks, such as limitations on recording accuracy if insufficient time has passed between samples and the restrictive nature of the cuff which can induce pain on a user. An alternative device that can monitor continuously would thus benefit people who are sensitive or need 24-hour monitoring. Ideally this would be a system that can be worn without discomfort and does not interfere with the user in any way. The ideal device would also allow continuous blood pressure monitoring throughout the cardiac cycle, independent of the level of physical activity of the user. Furthermore, this type of device would allow athletes to measure blood pressure during activity. To this end, a model is developed to describe blood pressure by measuring the arterial diameter on the radial artery and the pulse wave velocity (PWV) through it. Research suggests that these two metrics, along with the elasticity of an artery, can be used as a means to measure blood pressure non-invasively. This thesis focuses on the measurement of pulse wave velocity. The system design, including the hardware, is covered. The analysis techniques used to obtain raw signals, as well as the methods used to determine the PWV, will be discussed. The measurement location is described in detail. The results are shown to be comparable to values found in literature. However, due to lack of comparable measurement techniques, no direct comparisons between methods could be performed.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Electrical Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wenngren, Wilhelm Sven Ingemar

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/63867

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Wenngren, Wilhelm Sven Ingemar. Local pulse wave velocity detection over an arterial segment using photoplethysmography. master's thesis, University of British Columbia, 2017. http://hdl.handle.net/2429/63867