Back to search

University of British Columbia

Cardiac synchronized volumetric modulated arc therapy

Abstract

dc:description

Cardiac arrhythmias are abnormal heart rhythms that can adversely affect patients. The current treatment options include antiarrhythmic drug therapy and catheter ablation, both of which are associated with issues regarding efficacy and potential complications for complex arrhythmias. Cardiac radiosurgery, external beam therapy targeted at abnormal myocardial substrate, has the potential to be a non-invasive and efficient treatment option for arrhythmias. Intrafraction heart motion, however, must be accounted for to ensure accurate dose delivery to the target region. Our technique aims to minimize the dose delivered to normal tissues by synchronizing beam delivery with a cardiac signal, irradiating only during the quiescent intervals of the cardiac cycle (when heart motion is minimal) and adjusting the beam delivery speed in response to a changing heart rate. Although real-time treatment plan adaptation is not possible with the current linear accelerator systems, we demonstrated the feasibility of our technique by synchronizing beam delivery with sample ECG data. A conventional VMAT plan was split into 3 interleaved phases – each phase consists of alternating beam-on and beam-off arc segments, and the combination of all phases recreates the original plan. Each phase was synchronized with a sample cardiac signal, using movement of the treatment couch to adjust the durations of individual arc segments. The cardiac synchronized phases were created as XML beam files and were delivered in developer mode of the Varian TrueBeam system. Analysis of the trajectory logs showed that all beam-on segments were delivered during the quiescent intervals as planned. Film dosimetry was used to verify the dose delivery accuracy of the cardiac synchronized beams. A custom table was built and positioned over the treatment couch, allowing for a phantom placed on the table surface to remain stationary during beam delivery. Film was inserted in the phantom and irradiated using the original treatment plan, then a separate film was inserted and irradiated using the cardiac synchronized phases. Analysis of the films in FilmQA Pro returned a gamma passing rate of 99.4% (2%/2mm tolerance), indicating excellent agreement between the dose distributions of the original and cardiac synchronized beam deliveries.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Poon, Justin

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/66901

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Poon, Justin. Cardiac synchronized volumetric modulated arc therapy. master's thesis, University of British Columbia, 2018. http://hdl.handle.net/2429/66901