Back to search

University of British Columbia

Optimal micro phasor measurement unit placement for complete observability of the distribution system

Abstract

dc:description

The electrical power distribution system was originally designed for one way power flow. With the addition of renewable energy sources on the electrical grid, bidirectional power flow is now oc- curring and is causing previously unseen fluctuations in voltage. This, in addition to an increasing power demand from utility users, is decreasing grid stability and increasing the chance of cascad- ing blackouts. The distribution system needs to be monitored in real time so that minor issues relating to grid stability can be noted and fixed before they cascade into system failure. A micro phasor measurement unit (μPMU) is a device that is able to monitor the distribution system in real time. When placed at a node, it is capable of measuring the voltage phasor at the node and all incident current phasors to the node. However, the high cost of these devices, in addition to the communication infrastructure that would be needed, makes it unfeasible to place them at every node on a feeder. However, it is also not necessary to place them on every node since, if the line impedance is known, the surrounding node voltage values can be accurately calculated. Therefore, this thesis proposes an algorithm that optimally places μPMUs on distribution net- works for complete observability. This algorithm is based on a greedy algorithm which has many benefits such as fast computation time and high reliability. High reliability occurs when most of the distribution system is being monitored even in the event of a μPMU failure. The algorithm was tested on standard IEEE distribution feeders: 13-node, 33-node, 34-node, 37-node and 123- node. The results presented include the number of μPMUs needed for complete observability, computation time, and a measure of the reliability.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Electrical Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kerns, Brittney

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/67150

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Kerns, Brittney. Optimal micro phasor measurement unit placement for complete observability of the distribution system. master's thesis, University of British Columbia, 2018. http://hdl.handle.net/2429/67150