Back to search

University of British Columbia

4D-VMAT dose calculation using treatment-specific respiratory motions

Abstract

dc:description

The interplay between respiration-related tumour motion and modulated treatment delivery such as volumetric modulated arc therapy (VMAT) could contribute to differences between planned and delivered radiation dose distributions. The purpose of this work was to develop and experimentally validate a method to calculate the VMAT dose distribution in 4-dimensions (4D-VMAT dose calculation), accounting for tumour motion using the respiratory motion waveform recorded during each treatment fraction. The 4D-VMAT dose calculation method relies on the time sampling of machine parameters and respiratory amplitude-phase recorded during each fraction in the trajectory log file and motion waveform file, respectively. These files are recorded by a Varian TrueBeam LINAC with a respiratory motion management system. The phase information is used to sort the trajectory log file into ten discrete respiratory phases from which ten phase-specific VMAT plans are created and imported into the treatment planning system. The doses are re-calculated and summed to obtain the 4D-VMAT dose distribution. To experimentally validate the 4D-VMAT dose calculation, ten VMAT plans were created and delivered to a QUASAR respiratory motion phantom. The phantom was programmed with realistic respiratory motion waveforms from the QUASAR software database and motion amplitudes up to 15 mm were used. Each plan was delivered three times and a different waveform was used each time. Gafchromic EBT3 film was placed within the phantom to measure the delivered dose distribution. The 4D-VMAT calculated dose distributions were compared to the measured dose distributions and the agreement was assessed using gamma analysis with the 3%/3 mm dose-difference distance-to-agreement acceptance criteria and isodose and dose profile comparisons. The validation comparisons show that the 4D-VMAT dose calculation is able to reproduce fraction-specific dose distributions. There was a significant (p<0.001) improvement in the gamma passing rates for 4D-VMAT (M=89.4%, SD=8.5%) compared to the treatment planning system (M=71.6%, SD=16.4%).

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Medical Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ionele, Paul

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/67299

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Ionele, Paul. 4D-VMAT dose calculation using treatment-specific respiratory motions. master's thesis, University of British Columbia, 2018. http://hdl.handle.net/2429/67299