Back to search

University of British Columbia

Power loss estimation in LLC MOSFETs : a time interval analysis

Abstract

dc:description

LLC resonant converters have become a mainstream topology in DC/DC power conversion applications such as electric vehicle charging, renewable energy generation and low power energy conversion. This converter presents advantages such as the soft-switching of active devices, which reduces power losses in the energy conversion process, allowing for a more efficient operation when compared to hard-switched topologies. Losses in the MOSFETs of the inverting and rectifying stages of this converter should be accurately determined so to allow for proper heat management design and thermal dissipation. However, determination of losses through simulation can be challenging due to the significant difference between time constants of electrical and thermal phenomena. Moreover, the information presented by the datasheet of power electronic devices is often limited to select operating points, which may compromise the accuracy of power loss estimation. In order to overcome the limitations imposed by the datasheet, a detailed characterization of the main loss mechanisms in the operation of LLC MOSFETs is presented. To avoid the time-consuming and computationally-intensive process of simulation, steady-state time-domain expressions for the converter are developed, based on the electrical behavior of the topology. These equations, based on the Time Interval Analysis, are able to predict key electrical and thermal behaviours based on circuit design considerations and operating conditions, being easily implementable in software such as MATLAB or MS Excel. As verified by simulation and experimental results, estimation of losses using the proposed method is considerably more precise than using the well-established yet oversimplified First-Harmonic Approximation (FHA). In the inverting stage, the observed error in loss determination is reduced from an average of 19%, using FHA, to 2.8% using the proposed method. When it comes to the rectification portion of the circuit, the reduction in error observed is from 12% to 2%. Such improvement in power loss estimation before the converter is built is fundamental for the design of an agile and cost-effective thermal management approach which guarantees the integrity and reliability of the power electronics device.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Scabeni Glitz, Ettore Frederico

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/68004

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Scabeni Glitz, Ettore Frederico. Power loss estimation in LLC MOSFETs : a time interval analysis. master's thesis, University of British Columbia, 2018. http://hdl.handle.net/2429/68004