Back to search

University of British Columbia

Collision induced dissociation and mass spectrometry with the TITAN Multiple-Reflection Time-of-Flight Mass-Spectrometer

Abstract

dc:description

To better understand nuclear structure, high-precision mass spectrometry of radioactive nuclei is required. However, as the nuclei of interest move further away from stability, the half-lives and production yields drop. Furthermore, the cocktail beams are frequently contaminated with unwanted isobars and molecules which can obscure the species of interest and impede the measurement. To overcome these obstacles, the Multiple-Reflection Time-of-Flight Mass-Spectrometer (MR-ToF-MS) was commissioned at TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). The device can purify beams through the process of mass selective re-trapping and provide fast, precise, and high-sensitivity mass measurements. These two modes of operation can be used sequentially to conduct mass measurements of exceedingly contaminated beams. Furthermore, the technique of collision induced dissociation (CID) has been investigated and developed to allow for further suppression of molecular contamination. With CID, the molecular contamination can be suppressed by one to two orders of magnitude. This development was undertaken following a Ne experiment in which a large amount of molecular contamination was found. However, the measurement capabilities of the MR-ToF-MS was demonstrated during the mass measurement campaign of neutron-rich ²⁴-²⁶Ne in which relative uncertainties of approximately 10-⁷ were achieved. These measurements began to approach the "Island of Inversion" for the Ne isotope chain, and they further motivate the investigation of this region in the future, ultimately ending with the measurement of 31Ne.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jacobs, Andrew

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/71414

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Jacobs, Andrew. Collision induced dissociation and mass spectrometry with the TITAN Multiple-Reflection Time-of-Flight Mass-Spectrometer. master's thesis, University of British Columbia, 2019. http://hdl.handle.net/2429/71414