Back to search

University of British Columbia

Impact of biofilm layer on virus removal capacity and integrity testing of passive membrane systems

Abstract

dc:description

Passive membrane filtration is a self-sustained process where an ultra-low permeate flux is maintained by hydrostatic pressure (i.e. gravity) and little to no fouling control measures are used. Due to their ultra-low permeate flux and ease of operation, passive membrane systems are particularly suited for small scale applications, such as decentralized water treatment in small and remote communities. A key aspect of passive membrane filtration is the development of a structurally loose and permeable biofilm layer that enables a sustainable flux to be achieved. The biofilm layer of passive membrane systems has also been associated with improved removal of humic acids, polysaccharides, proteins, assimilable organic carbon and microcystins. The present study investigated the contribution of the biofilm layer to the virus removal capacity of passive membrane systems. Intact and breached passive membrane modules were studied. Breach sizes considered ranged from 20 to 180µm. Challenge tests (CTs) identified an increase of more than 2.0 log in the log removal value (LRV) for viruses of both intact and breached passive membranes when a biofilm layer was present. As a result, intact and breached passive membranes consistently achieved an LRV for viruses of more than 4.0 log. The use of pressure decay tests (PDTs) to estimate the LRVs of passive membrane systems was also studied. The LRVs estimated using the standard PDT approach did not reflect the increase in LRVs detected in the CTs. Results suggested that the biofilm layer grows on top of the breaches, acting as a secondary barrier to contaminants that would otherwise bypass treatment by flowing through the breach. The standard PDT approach failed to estimate the LRVs of passive membranes because it was not developed to take into account the additional removal provided by the biofilm layer. An alternative integrity testing protocol for passive membrane systems is provided, which includes a modified PDT approach for estimation of LRVs.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Civil Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tobias Costa de Oliveira, Amanda

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/71930

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Tobias Costa de Oliveira, Amanda. Impact of biofilm layer on virus removal capacity and integrity testing of passive membrane systems. master's thesis, University of British Columbia, 2019. http://hdl.handle.net/2429/71930