Back to search

University of British Columbia

Measurement of the arterial input function from radial MR projections

Abstract

dc:description

Dynamic Contrast-Enhanced MRI (DCE-MRI) data may be used to non-invasively investigate the health status of tissue. The technique requires that the concentration of a contrast agent vs. time curve is known in both the tissue of interest and in a blood vessel feeding the tissue - commonly referred to as the arterial input function (AIF). Physiologically relevant parameters are extracted through Pharmacokinetic modeling, though the accuracy is known to be highly sensitive to the quality of the acquired data. It is difficult to get a good measurement of the AIF in pre-clinical studies in mice due to their small body size and limited number of vessels of a sufficient size. As a result, several groups use a population averaged curve from the literature. This curve does not account for inter or intra-individual differences, and impacts the accuracy of the fit parameters. We propose a new projection-based measurement that measures the AIF from a single trajectory in k-space, which provides a temporal resolution equal to the repetition time (TR). This AIF is measured in the mouse tail due to the simpler geometry void of highly enhancing organs nearby. The projection-based AIF is advantageous as it allows for the acquisition of DCE data, in the tissue of interest, between measurements without affecting the temporal resolution of either data set. We set up a dual coil experimental platform that acquires AIF data at the mouse tail and DCE data at the tumour. Our technique allows for data optimization at both locations, without restricting the temporal or spatial resolutions of the AIF or DCE data. It may be applied to any pre-clinical study using mice or rats.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Moroz, Jennifer

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/72065

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Moroz, Jennifer. Measurement of the arterial input function from radial MR projections. doctoral thesis, University of British Columbia, 2019. http://hdl.handle.net/2429/72065