Back to search

University of British Columbia

Aquatic treadmill running : exercise testing, prescription, and the physiological response

Abstract

dc:description

Background: Water immersion for exercise training, recovery, and rehabilitation has been a popular and effective modality for a variety of disciplines. Recent technological advancements have led to more sports teams, research facilities, and rehabilitation clinics using aquatic treadmills (ATM) as a modern form of aquatic exercise. Purpose: The purpose of this investigation was to; 1) develop graded exercise testing criteria and evidence-based recommendations for ATM testing, 2) examine the cardiovascular response during maximal and submaximal ATM running, including ventilatory thresholds, 3) examine the hemodynamic response during submaximal ATM running, 4) determine the influence of small changes in water temperature on cardiovascular and hemodynamic responses during ATM running, and 5) explore the relationship between anthropometric measures and physiological alterations during ATM running. Methods: Participants completed a series of interventions on a land treadmill (LTM) and a HydroWorx 2000 ATM in a crossover design. Participants completed maximal graded exercise tests with a verification phase on each treadmill to compare maximal and submaximal cardiorespiratory responses, as well as determine ventilatory thresholds (VT1&VT2). Three submaximal running protocols incorporating multiple water temperatures and distances from a resistance jet were completed to determine the influence of these variables on the cardiorespiratory and hemodynamic responses. Lastly, the relationship between anthropometric measures and physiological responses during ATM running was examined. Results: Running between 0.61 metres and 0.76 metres from the resistance jet elicits the greatest cardiovascular response. The maximal and submaximal cardiorespiratory responses are similar between LTM and ATM with the exception of a lower maximal heart rate during ATM running. The use of a verification phase to confirm the attainment of V̇O2max is appropriate. VT1 and VT2 occur at similar points in each environment. ATM running alters submaximal hemodynamic responses, specifically a lower cardiac output and stroke volume. A change in water temperature of only 4C can alter the cardiovascular and hemodynamic responses during submaximal running. Anthropometric measures influence the ATM and LTM responses differently. Conclusions: These results provide compelling insight into the use of ATM to aid practitioners globally in achieving their desired results and provide a recommended standard of practice to follow in further research.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Experimental Medicine
Grantor dc:publisher
University of British Columbia
Year dc:date
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Held, Nicholas

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/75296

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Held, Nicholas. Aquatic treadmill running : exercise testing, prescription, and the physiological response. doctoral thesis, University of British Columbia, 2020. http://hdl.handle.net/2429/75296