Back to search

University of British Columbia

Validation of a non-invasive assessment of pulmonary gas exchange during exercise in hypoxia

Abstract

dc:description

Background: Pulmonary gas exchange efficiency, determined by the alveolar-to-arterial PO₂ difference (A-aDO2), progressively worsens during exercise at sea-level; this response is further augmented during exercise in hypoxia. Traditionally, pulmonary gas exchange efficiency is assessed through measurements of ventilation and end-tidal gases paired with direct arterial blood gas (ABG) sampling. Since these measures have a number of caveats, particularly invasive blood sampling, the development of new approaches for the non-invasive assessment of pulmonary gas exchange is needed. Research Question: Is a non-invasive method of assessing pulmonary gas exchange valid during rest and exercise in acute hypoxia? Study Design and Methods: Twenty-five healthy participants (10 female) completed a staged maximal exercise test on a cycle ergometer in a hypoxic chamber (FIO₂=0.11). Simultaneous ABGs via a radial arterial catheter and non-invasive gas exchange measurements (AGM100) were obtained in two-minute intervals. Non-invasive gas exchange efficiency, termed the O₂ deficit, was calculated from the difference between the end-tidal and the calculated PaO₂ (via pulse oximetry and corrected for the Bohr effect by using the end-tidal PCO₂). Non-invasive O₂ deficit was compared to the traditional alveolar to arterial oxygen difference (A-aDO₂) using the traditional Riley analysis. Results: Under conditions of rest at room air, hypoxic rest and hypoxic exercise, strong correlations between the calculated gPaO₂ and directly measured PaO₂ (R²=0.97; p<0.001; mean bias =1.70 mmHg) were observed. At hypoxic rest and exercise, strong relationships between the calculated and directly measured PaO₂ (R²=0.68; p<0.001; mean bias =1.01mmHg) and O₂ deficit with the traditional A-aDO₂ (R²=0.71; p<0.001; mean bias =5.24mmHg) remained. Interpretations: Our findings support the use of a non-invasive measure of gas exchange during acute hypoxic exercise in heathy humans. Further studies are required to determine if this approach can be used clinically as a tool during normoxic exercise in patients with pre-existing impairments in gas exchange efficiency.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Health and Exercise Sciences
Grantor dc:publisher
University of British Columbia
Year dc:date
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Howe, Connor Aaron

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/75633

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Howe, Connor Aaron. Validation of a non-invasive assessment of pulmonary gas exchange during exercise in hypoxia. master's thesis, University of British Columbia, 2020. http://hdl.handle.net/2429/75633