Back to search

University of British Columbia

Stability and electrochemical regeneration of activated carbon electrodes for capacitive deionization

Abstract

dc:description

The stability and electrochemical regeneration of activated carbon electrodes used for Capacitive Deionization have been investigated. To assess the electrode state, electrochemical properties such as capacitance and potential at the point of zero charge (EPZC) were monitored and complemented by elemental composition, wettability and bulk porosity analysis. Long-term cycling was performed with electrolytes containing dissolved organic matter (DOM) and iron (II) under anaerobic and aerobic conditions. It was found that DOM, at concentrations of up to 40 mg L-¹, had a marginal impact on capacitance loss and relocation of the EPZC. On the other hand, the scaling nature of iron was apparent from early cycling stages, in waters containing as little as 0.2 mg Fe²⁺ L-¹. In all cases performed, elemental composition analysis demonstrated that incorporation of oxygen to the surface occurred predominantly during the first 15 to 20 cycles. Specifically, the oxygen content increased by a factor of four. Over this time frame, the contact angle decreased from approx. 130˚ to 34˚, on average; which indicated an increase in electrode wettability. In addition, cycling experiments with simple electrolytes revealed improved electrode stability as cycling time increased and as pH decreased. Degradation tests conducted using a two-electrode cell demonstrated the effect of reaction coupling between the processes of carbon corrosion and oxygen reduction. As a result, electrode decay occurred at an accelerated rate. Electrochemical regeneration was proven successful at recovering the electrode capacitance but not at regressing the EPZC. Their corresponding response surfaces were mapped through a 32-factorial design of experiments and revealed a significant potential dependence. Further tests revealed a point of maximum recovery near a potential of -1.68 V vs RHE and 50 s of holding time. Furthermore, the contribution of a regenerative step to the long-term electrode stability was assessed. In general, an improved retention of capacitance was observed during the first 25 cycles. However, it was noted that most of the capacitance recovered was lost in the subsequent degradation cycles. Consequently, the apparent initial improvement did not translate to an extension of the electrode lifetime, deeming this approach inadequate to mitigate the effect of carbon corrosion.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Chemical and Biological Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Serrano Mora, Adrian

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/75658

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Serrano Mora, Adrian. Stability and electrochemical regeneration of activated carbon electrodes for capacitive deionization. doctoral thesis, University of British Columbia, 2020. http://hdl.handle.net/2429/75658