Back to search

University of British Columbia

Combining Monte Carlo simulations and detector measurements for a novel quality assurance system of assembled brachytherapy eye plaques.

Abstract

dc:description

Quality assurance of radiation therapy devices used to treat cancer is important to assure successful treatment and prevent over- or under-dosage. For brachytherapy eye plaques, the current standard procedure involves measuring the individual seed air-kerma strengths in a well chamber and visually inspecting the plaque. This leaves room for errors to occur between seed verification, plaque assembly, and implantation. In addition, the availability of manufacturer-assembled commercial eye plaques has increased, where independent, pre-implantation verification is limited to verifying the seed strength of additional loose seeds from the same seed lot. Currently, no commercially available system or technique exists for routine quality assurance of assembled eye plaques. This thesis investigates whether a flat panel image detector can be used in combination with Monte Carlo simulations, to develop a quality assurance system for assembled I-125 and Pd-103 brachytherapy eye plaques. The detector is used in conjunction with an acrylic plaque holder to record the 2D dose distribution of the plaque perpendicular to the plaque central axis. The system is simulated in Monte Carlo to generate a 3D dose distribution. Calibrating the detector relative to the Monte Carlo results allows comparisons between simulated and measured plaques, making it possible to verify the central dose rate of the plaque and to verify the 2D dose distribution in the detector plane using gamma index analysis. Results showed good agreement between the dose distributions and central strengths of detector measured and simulated results for a variety of seed strengths and seed arrangements, enabling the detection of dead or missing seeds. A procedure was established to compare the results to TG-43 dose calculations used in treatment planning. The method was tested on BC Cancer in-house design acrylic eye plaques and a commercial Eye Physics dummy plaque. The detector showed strong attenuation for incoming radiation with large angles of incidence, limiting the applicability of this method for individually collimating plaques. Overall, this study showed that a flat panel imaging detector and Monte Carlo simulations can be combined for routine quality assurance and verification of assembled eye plaques without individual seed collimation.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Möehle, Swantje D.

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/76967

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Möehle, Swantje D.. Combining Monte Carlo simulations and detector measurements for a novel quality assurance system of assembled brachytherapy eye plaques.. master's thesis, University of British Columbia, 2020. http://hdl.handle.net/2429/76967