Back to search

University of British Columbia

The design and development of a phantom for use in dynamic spect imaging

Abstract

dc:description

It has been suggested that the rate of tracer extraction from certain organs reflects the functional ability of that organ. The determination of the kinetic rates associated with extraction could therefore potentially provide a useful measure of organ function and could help in the diagnosis of disease. Dynamic SPECT is one imaging modality that attempts to determine these kinetic rates in three dimensions. A dynamic heart-in-thorax phantom has been developed for testing dynamic SPECT reconstruction methods. This phantom consists of a plastic myocardial volume containing smaller "defect" volumes, and a central blood pool. Surrounding the heart phantom is a larger thorax phantom which provides a non-uniform attenuating medium. The heart volumes are loaded with activity and washed out with water, thus producing the same type of activity decay that is seen to occur in the metabolism of fatty acids in the myocardium. By varying the flow rate of water into the phantom, different washout times can be obtained. Additionally, the phantom can be used in a variety of applications including multiple exponential decay and the investigation of input functions. Testing of the phantom using both planar dynamic and image based SPECT protocols show that the phantom accurately reproduces preset washout rates to within 10%. With this level of accuracy attained, we feel the phantom can confidently be used in the development of new dynamic SPECT reconstruction algorithms.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
1998

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Farncombe, Troy

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/7841

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Farncombe, Troy. The design and development of a phantom for use in dynamic spect imaging. master's thesis, University of British Columbia, 1998. http://hdl.handle.net/2429/7841