Back to search

University of British Columbia

Accuracy of commercially available implant planning softwares

Abstract

dc:description

Objectives: Cone-Beam Computed Tomography (CBCT) was first developed 29 years ago and came into commercial use in 1999 and has over the last decade been increasingly applied to almost every area of dental practice. This is due to 3D visualization of teeth and supporting tissues, high spatial resolution, low radiation, and minimal operating time compared to medical computed tomography. The CBCT images are read by an accompanying viewer or a treatment planning software. Currently, there is little information on comparing accuracy of commercially available implant planning softwares. Therefore, the aim of this study was to assess the accuracy of four popular implant planning software (coDiagnostix, DTX, Simplant, and BlueSkyPlan) by identifying the mandibular canal using the free hand nerve marking tool. Methods: Two De-fleshed human mandibles were acquired for study. Various regions of the mandibles were evaluated including canine, premolars, and molars. Gutta-percha was fixated in buccal and lingual aspects of the aforementioned regions. Mandibles were scanned in low (.30mm voxel size) and high (.18mm voxel size) resolution along with variation of mA values including 3.2, 4, and 5. DICOM files were imported into the four implant planning softwares for analysis. After image analysis, specimen were sectioned with a reverse-cutting saw in all evaluated regions. For gold standard measurements, a digital caliper was used in anatomical sections to measure comparable areas. Results: ANOVA analysis demonstrated that there is no statistical significance between the gold standard and different softwares when calculating for accuracy. When calculating for sensitivity, it appears that coDiagnostix has the highest value out of the four softwares. Conclusions: Varying mA and voxel size values does not impact the accuracy of four different softwares. It appears that coDiagnostix has the highest sensitivity values when using the most common settings for CBCT image acquisition.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Craniofacial Science
Grantor dc:publisher
University of British Columbia
Year dc:date
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sandlas, Shamsher
Contributors dc:contributor
  • MacDonald, David, 1955-

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/78504

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Sandlas, Shamsher. Accuracy of commercially available implant planning softwares. master's thesis, University of British Columbia, 2021. http://hdl.handle.net/2429/78504