Back to search

University of British Columbia

Modelling inhomogeneous magnetization transfer in myelin water and intra-/extra-cellular water in normal and injured excised rat spinal cord

Abstract

dc:description

Inhomogeneous magnetization transfer (ihMT) and myelin water imaging (MWI) were combined to separate the ihMT signal in the myelin water (MW) and intra-/extra-cellular water (IEW). A bi-exponential was used to fit the T2 decays of each saturation type, to quantify the ihMT effect in the MW and IEW pool, separately. Here, we proposed a model that included the dipolar reservoirs to the original four pool model to better interpret our ihMTR, ihMTR-MW, and ihMTR-IEW values. We took data at 11 different levels of T1D filtering (11 Tswitch times) for 9 formalin-fixed rat spinal cords, 3 healthy and 6 injured cords. We were able to reasonably fit the ihMTR-MW decay curve but could not capture the early data points of the ihMTR-IEW decay in our model, which may have yielded an inaccurate T1D (non-myelin) measurement. Our T1D (myelin) values were relatively close to previously measured T1D values and we saw a significant drop in T1D (myelin) in the 3 weeks post-injury spinal cords in the fasciculus gracilis region. Thus, our results suggest that T1D (myelin) may be a potential marker for separating functional myelin from myelin debris; however, more studies are required to confirm this result. Additionally, modifications need to be made to the model to improve the fit of the ihMTR-IEW data points.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lam, Michelle H.
Contributors dc:contributor
  • Kozlowski, Piotr

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/80011

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Lam, Michelle H.. Modelling inhomogeneous magnetization transfer in myelin water and intra-/extra-cellular water in normal and injured excised rat spinal cord. master's thesis, University of British Columbia, 2021. http://hdl.handle.net/2429/80011