Back to search

University of British Columbia

The effect of proportional assist ventilation on diaphragm electrical activity

Abstract

dc:description

The diaphragm is the largest contributing muscle in a spontaneous breath. Classically, when failure in this muscle occurs, mechanical ventilation is implemented to reduce acute respiratory failure. The proportional assist ventilator (PAV) is a type of mechanical ventilator that can maintain gas homeostasis in dynamic exercise. However, PAV’s effect on the diaphragm, accessory respiratory muscles, and effectiveness during lower intensity exercise is still unclear. PURPOSE: To investigate the diaphragm electrical activity during low exercise intensity (10% below gas exchange threshold (GET)) while reducing the work of breathing via a PAV. METHODS: 8 participants (n = 4 male, n = 4 female; 26.8 ± 1 years) completed two days of testing. On day one, subjects performed a maximal VO2 exercise test on a cycle ergometer. On day 2, subjects cycled at 10% below GET while alternating breathing on the PAV and spontaneously. Electromyography of the diaphragm (EMGdi), scalenes (EMGSCA), and sternocleidomastoids (EMGSCM), work of breathing (WOB), pressure time product of the esophagus (PTPes), diaphragm (PTPdi) and gastric (PTPga) were measured throughout the experimental protocol. RESULTS: WOB was lower while breathing on the PAV during medium (p < 0.05) and high (p < 0.01) unloading conditions. PTPes was significantly lower while breathing on the PAV for low, medium, and high unloading assistance (p < 0.05; p < 0.01; p < 0.01) compared to spontaneous breathing. PTPdi was significantly lower while breathing on the PAV for low, medium, and high comparisons (p < 0.05, p < 0.01; p < 0.01) compared to spontaneous breathing. While PTPgas was significantly lower when breathing on the PAV during high levels of unloading (p < 0.01) compared to spontaneous breathing. EMGdi was lowered while breathing during all PAV unloading levels (low, medium, and high) compared to spontaneous breathing (p < 0.05; p < 0.05; p < 0.05). EMGSCA was reduced when breathing on the PAV during high unloading versus spontaneous breathing (p < 0.05). EMGSCM showed no reductions between PAV unloading levels and spontaneous breathing. CONCLUSION: PAV reduces WOB during exercise below 50% of VO2MAX and simultaneously reduces the diaphragm electrical activity.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Kinesiology
Grantor dc:publisher
University of British Columbia
Year dc:date
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gerson, Emily Ann Marie
Contributors dc:contributor
  • Sheel, A. William

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/80029

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Gerson, Emily Ann Marie. The effect of proportional assist ventilation on diaphragm electrical activity. master's thesis, University of British Columbia, 2021. http://hdl.handle.net/2429/80029