dc:description

Several metrics for assessing human thermal response have been proposed in the literature, with skin temperature (TSkin) and skin relative humidity (RHSkin) being among them. These metrics aim to describe human thermal perception of their thermal environment. Traditional parameter analysis involves multiple expensive, complex, invasive devices that require unnatural adjustments to the user, may result in poor signal quality, and provide unreliable feedback on thermal status. We tested a wearable system containing TSkin and RHSkin sensors that can perform thermoregulatory evaluation that will circumvent the limitations of the traditional thermal analysis systems. 19 healthy adults completed validation testing in a high intensity exercise protocol with our wearable sensor system. Band sensors were validated against two types of iButtons (Hygrochrons for relative humidity, Thermochrons for temperature). The comparisons were done between the Bands and three different averaged locations of iButtons: abdomen, torso, and whole body. Pearson’s correlation and Bland Altman Analysis were used to compare the Bands to the Hygrochrons. Except for the abdomen location, the RH’s calculated by our wearable sensor system showed high to very high correlation with the Hygrochrons (r = 0.862 to 0.967) but due to the large error cannot be used as a reference. For TSkin, a t-test found that the only non-significant differences were between the Bands and the whole-body averages of Thermochrons. One-Way ANOVA testing found that the location of Hygrochrons and Bands led to significantly differences in RH measurements (p<0.01), however the location of the Thermochrons did not lead to significant different in TSkin measurements (p≥0.22). A two-tailed t-test compared all data with changes pre-exercise, during exercise, and recovery. The validity of comparisons of all HR, RHSkin, and TSkin measurements to qualitative thermal perception votes was tested with Spearman’s Rank correlation and found a significant relationship between torso thermochrons and personal tolerance, personal acceptability, thermal preference, and thermal perception scales, and between mean heart rate and thermal perception, thermal preference, and personal acceptability (p<0.05). A wearable sensing system for thermal analysis is an upcoming and exciting viable candidate to supplement traditional assessment techniques and make thermoregulatory assessment methods less complex and demanding.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Crowley, Madeline Monahan
Contributors dc:contributor
  • Servati, Peyman

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/82149

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Crowley, Madeline Monahan. A wearable sensor system to relate thermoregulatory signals to comfort. master's thesis, University of British Columbia, 2022. http://hdl.handle.net/2429/82149