Back to search

University of British Columbia

Quantifications and characteristics of dynamic soft tissue artifacts captured by wearable inertial measurement unit sensors

Abstract

dc:description

Inertial measurement units (IMUs) are a prevalent component in wearable sensor systems to study motion in unconstrained environments by measuring both linear acceleration and angular velocity at a point of interest on the human body. However, wearable sensors are often worn on soft tissue that is excited during impulsive impacts, producing dynamic soft tissue artifact measurement errors. This thesis quantifies the error caused by dynamic soft tissue artifacts to IMU sensors with different sensor mass and placement when mild impulsive impacts are delivered to the lower extremity using empirical signal analysis and model-based predictions. Data were collected from three IMU sensors attached at the anterior and posterior center of the dominant shank, and at the back of the ankle of 10 participants (5 females, 5 males). We varied the mass of the two shank IMUs from 5 grams to 37 grams in 8-gram increments. Impacts were generated by dropping the shank freely onto a foam pad placed on a force plate from a height of 21.6 cm. Ground truth vertical linear acceleration measurements from the ankle IMU were first cross-validated against the force plate. We then determined both posterior and anterior IMUs overestimated the ground truth peak vertical linear acceleration measurement by 117.9% and 55.1%, respectively. The posterior IMU had greater overestimations, suggesting more severe dynamic soft tissue artifacts, while errors generally decreased with increasing mass, suggesting a mitigating effect from adding sensor mass. We next assessed post-impact oscillations, which we determined lasted 0.32±0.07 seconds with a frequency of 9.79±2.68 Hz on the posterior and 0.15±0.05 seconds with a frequency of 18.33±12.24 Hz on the anterior. As sensor weight increased, the oscillation duration increased linearly while the frequency decreased for both anterior and posterior IMUs. This suggests that increasing sensor mass amplifies post-impact dynamic soft tissue artifact errors. These results and dependencies were confirmed by modeling dynamic soft tissue artifacts as double spring mass damper systems. In conclusion, the dynamic soft tissue artifacts directly relate to the accuracy of kinematic measurement in IMU sensors with a dependence on sensor mass and placement.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Rong, Shenyi
Contributors dc:contributor
  • Kuo, Calvin

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/82903

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Rong, Shenyi. Quantifications and characteristics of dynamic soft tissue artifacts captured by wearable inertial measurement unit sensors. master's thesis, University of British Columbia, 2022. http://hdl.handle.net/2429/82903