Back to search

University of British Columbia

Influence of gingival retraction on the accuracy of an intraoral scanner for subgingival finish lines

Abstract

dc:description

Purpose: The aim of this study was to evaluate the influence of horizontal gingival displacement on the accuracy of an intraoral scanner (IOS) with 0.5 and 1mm subgingival finish lines. Materials and Methods: A 3D printed resin dental model was fabricated with a removable milled zirconia die of tooth #46 full crown preparation and 3D printed resin gingiva. A supragingival control group, and six test groups were designed and fabricated with varying horizontal gingival displacement (0.12mm, 0.25mm 0.45mm) each with subgingival finish line positions of 0.5mm (groups 1 to 3, respectively) and 1mm (groups 4 to 6, respectively). The Trios3 (3Shape) IOS was used to scan 18 samples per group and the scans were superimposed with a reference scan of the die without the gingiva. Absolute marginal discrepancies (AMD) between test and reference scans were measured at 8 fixed points around the prep, and at the largest marginal discrepancy (LMD) site. The one-way ANOVA test measured statistical differences between the groups, and the Games-Howell test compared each pair of groups. Results: The highest mean AMDs at fixed sites were on the distolingual surface for all study groups including the control group (p<0.001), but with inconsistent statistical differences between groups. Group 5 showed the highest mean AMD of 0.203mm followed by Group 4 at 0.194mm, while the control group showed 0.054mm, which was well below a clinically acceptable crown margin gap of 100μm. Mean LMDs were highest in Groups 1 and 4 (0.12mm displacement) with 0.913 and 1.130mm respectively, whereas the lowest values were in group 3 and 6 (0.45mm displacement) with 0.162 and 0.113mm, which were still higher than the control 0.065mm. Differences in LMDs between groups were all statistically significant (p<0.001) except between Groups 2 and 5, and Groups 3 and 6. Conclusion: Within the study limitations, the accuracy of an IOS is significantly reduced when capturing subgingival finish lines. Moreover, the amount of horizontal gingival displacement was shown to have a significant effect in improving the accuracy of digital impressions. A minimum horizontal gingival displacement of 0.25mm should be achieved by gingival retraction techniques to improve scanning quality.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Craniofacial Science
Grantor dc:publisher
University of British Columbia
Year dc:date
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Al Assadi, Faisal
Contributors dc:contributor
  • Bryant, Ross

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/85876

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Al Assadi, Faisal. Influence of gingival retraction on the accuracy of an intraoral scanner for subgingival finish lines. master's thesis, University of British Columbia, 2023. http://hdl.handle.net/2429/85876