Back to search

University of British Columbia

Assessing three-dimensional soft tissue changes and the prediction of hard tissue changes after orthognathic surgery with a novel digital workflow

Abstract

dc:description

Objectives: To investigate the application of virtual surgical planning (VSP) for three-dimensional (3D) hard and soft tissue assessment in orthognathic patients with a novel digital workflow. Methods: Twenty-one consecutively treated pre-surgical patients were selected from two private oral surgeon’s offices. Soft tissue scans of the face with the Artec Space Spider and intra-oral scans, were taken one month before surgery (T0), then two months (T1), and six months (T2) after orthognathic surgery. Cone beam CTs (CBCTs) were taken only at T0 and T1. Serial 3D soft tissue region and landmark changes were assessed by root mean square (RMS) after superimposing the T1 and T2 scans over T0 in Geomagic Control X software, separately. The achieved hard tissue landmark changes were assessed and compared with the VSP three-dimensionally. The correlation of hard and soft tissue changes was also tested with correlation coefficient tests. The differences in soft and hard tissue changes between the Invisalign® clear aligner and fixed appliances samples were also compared with two sample-independent t-tests. Results: The Artec Space Spider captured soft tissue images with the same accuracy as CBCT. This digital workflow was accurate, repeatable, and reproducible. From two to six months after surgery, there was clinically significant soft tissue relapse of maxillary (16-69%) and mandibular (9-36%) regions and landmarks which were highly variable and asymmetrical. Predicted virtual surgical movements were highly accurate (5-15%) for hard tissue landmarks. Ratios of soft tissue to hard tissue changes measured in three dimensions two months following surgery were similar to findings in literature measured in two dimensions. There were generally no differences in changes in soft and hard tissue landmarks or VSP for fixed versus Invisalign patients. Conclusions: The Artec Space Spider can be used as part of a novel digital workflow for VSP. Clinicians and patients should have great confidence that VSP is highly accurate and applicable for both fixed and Invisalign cases. Additionally, clinically significant soft tissue relapse can be anticipated between two to six months after surgery.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Craniofacial Science
Grantor dc:publisher
University of British Columbia
Year dc:date
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ho, Jeremy Ka Chun
Contributors dc:contributor
  • Zou, Bingshuang

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/86651

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Ho, Jeremy Ka Chun. Assessing three-dimensional soft tissue changes and the prediction of hard tissue changes after orthognathic surgery with a novel digital workflow. master's thesis, University of British Columbia, 2023. http://hdl.handle.net/2429/86651