Back to search

University of British Columbia

Ultraviolet disinfection of unfiltered water supplies : exploring effects of particle-microorganism association and efficiency enhancement strategies

Abstract

dc:description

Traditional quality indicators used in water treatment facilities have limitations in assessing particle-related challenges and system performance under challenging conditions. This study seeks to explore the impacts of particle-microorganism interactions on ultraviolet (UV) disinfection performance, identify water quality indicators that best describe performance, and suggest innovative methodologies to mitigate these effects on disinfection performance. Several sampling points of two full-scale treatment plants, receiving surface water without filtration, were monitored to identify the impacts of particulates on UV performance. The research established a link between zeta potential or surface charge and disinfection effectiveness and results suggest that conventional water quality indicators do not adequately capture particle effects on UV disinfection. An examination of methods for detecting particle-microorganism associations was conducted to devise an experimental approach in line with contemporary research directions and supported by a reasonable theoretical foundation. To further explore the impact of challenging source conditions on UV disinfection, the second objective was to study a wider variety of water conditions. Results suggested that disinfection could be compromised even at low turbidities (< 1 NTU), depending on the water matrices. Furthermore, complex interactions with background source water quality and additional particulate and dissolved matters were observed and suggested that non-specific indicators (turbidity or UVT) as opposed to specific indicators (zeta potential) should be used with caution when predicting the UV performance specifically under challenging conditions. Overall, zeta potential enhanced UV disinfection predictability. The observed influence of zeta potential on UV performance led to proposing a UV enhancement strategy in relation to problems regarding particles. A new line of study was started to identify if manipulating particle-microorganism associations through zeta potential modifications was viable as disinfection enhancement strategy. Assessing zeta potential manipulation effects on water quality using bacterial and viral surrogates showed that samples with highly negative zeta potential result in reduced particle-microorganism associations and increasing disinfection efficacy. This research highlights the limitations of conventional indicators in assessing UV disinfection in challenging conditions. Zeta potential emerged as a key factor in improving assessment, leading to exploration of a novel pre-treatment approach for facilities that may experience significant impacts due to particulates.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Civil Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Soleimanpour Makuei, Mehrnaz
Contributors dc:contributor
  • Peleato, Nicolas M.

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/88374

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Soleimanpour Makuei, Mehrnaz. Ultraviolet disinfection of unfiltered water supplies : exploring effects of particle-microorganism association and efficiency enhancement strategies. doctoral thesis, University of British Columbia, 2024. http://hdl.handle.net/2429/88374