Combined torsional and cyclic fatigue resistance of rotary endodontic files
Abstract
dc:descriptionThis study presents a novel model of instrument testing that combines torsional and cyclic fatigue (CF) stresses simultaneously, aiming to evaluate the impact of torque at the tip of a rotary file on resistance. Fractographic analysis was performed on the fractured files to further understand the mode of failure. Size F2 ProTaper Ultimate (PTU) and ProTaper Gold (PTG) files from Dentsply Sirona were rotated with either a 30° or 60° curvature angle and 5mm radius, and the file positioned with the maximum radius at D12 to simulate significant coronal curvature. The file tip was aligned with a torque sensor to measure the braking force that was applied with an electric motor, replicating file action within the canal. The number of cycles to failure (NCF) was recorded for tip torques of 50, 100, 150, and 200 gcm. In a 60° canal, PTU files performed roughly three times better than PTG files with a 50 gcm tip torque. PTU files showed a significant decrease in NCF at each increased tip torque with an 85% reduction in NCF at 200 gcm. CF resistance dropped 50% in PTG files under the same conditions. In a 30° canal, both files performed similarly at low torques; however, PTU was much more sensitive to an increasing torque load. In both canals, PTU failed at a lower NCF than PTG when tested at 200 gcm. DSC confirmed that both files were made from the same alloy and SEM analysis confirmed no samples fractured due to torsional failure. These findings emphasized the critical role of torque control during the instrumentation of curved canals. Although thinner diameter files are thought to be more CF resistant and, therefore, may be better for instrumenting severely curved canals, this benefit appears to be negated in a clinical setting where the file tip is experiencing torsional forces. Furthermore, fractographic analysis may underestimate the role of the torque files experience by classifying fractures as CF. Sole reliance on the manufacturer’s recommended torque setting may create a false sense of security, highlighting the need for precise torque management to optimize treatment outcomes.
Degree
thesis:*- Name thesis:degree_name
- Master of Science - MSc
- Level thesis:degree_level
- master's
- Discipline thesis:degree_discipline
- Craniofacial Science
- Grantor dc:publisher
- University of British Columbia
- Year dc:date
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Bostrom, Brian
- Contributors dc:contributor
-
- Hieawy, Ahmed
Rights
dc:rights- Statement dc:rights
-
- Attribution-NonCommercial-NoDerivatives 4.0 International
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/2429/88597