Back to search

University of British Columbia

Clinical applications of 3D polymer gel dosimetry with cone-beam computed tomography readout in dosimetric and spatial accuracy verification

Abstract

dc:description

Radiation therapy is used to treat various types of cancers. The technologies in radiation delivery continue to advance rapidly. Currently, we are able to accurately target a radiation beam to a tumour volume by conforming the shape of the beam to the complex tumour shape. However, with that, there is a need for radiation dose detection tools that accurately capture the complex dose distribution in 3D space in order to verify the accuracy and precision of a treatment delivery. The purpose of this work is to implement a promising solution to this clinical challenge that utilizes a 3D NIPAM polymer gel dosimetry system with CBCT readout to verify the dosimetric and spatial accuracy of stereotactic radiosurgery (SRS) and spatially fractionated radiotherapy (SFRT) technique. Three main objectives of this work are 1) to evaluate the reproducibility of a NIPAM gel dosimetry workflow between two institutions, by implementing three identical verification plans in order to demonstrate its wide scale applicability in commissioning advanced radiotherapy techniques. In the study, two separate gel analysis pipelines were utilized based on the individual institution’s preference. 2) to commission two SRS techniques; HyperArc® (Varian Medical Systems, Palo Alto CA) to treat brain metastases and a virtual cone technique to treat trigeminal neuralgia. In the virtual cone study, an end-to-end spatial accuracy test of the treatment delivery was performed using a 3D printed anthropomorphic phantom. The dosimetric accuracy of the gel dosimetry system was benchmarked against a gold standard, film dosimeter. 3) utilizing a traditional dosimeter solely to verify the treatment delivery accuracy of SFRT is incredibly challenging and inefficient due to the heterogenous dose distribution generated in three-dimensional space. Therefore, goal of the final study is to demonstrate the application of the gel dosimetry system to commission SFRT technique. A semi-automated SFRT planning approach was utilized to generate a verification plan on a gel dosimeter for analysis. This work presents novel applications of a gel dosimetry workflow in two advanced radiotherapy deliveries (SRS and SFRT). The dosimetric and spatial accuracy with this type of gel dosimetry analysis is invaluable for the clinical commissioning process.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Medical Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kunkyab, Tenzin
Contributors dc:contributor
  • Jirasek, Andrew

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/88830

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Kunkyab, Tenzin. Clinical applications of 3D polymer gel dosimetry with cone-beam computed tomography readout in dosimetric and spatial accuracy verification. doctoral thesis, University of British Columbia, 2024. http://hdl.handle.net/2429/88830