Back to search

University of British Columbia

Design and evaluation of a device to prevent instrument drops during surgery

Abstract

dc:description

Within the dynamic and high-stakes environment of the operating room (OR), the inadvertent dropping of surgical instruments represents a notable challenge, with implications for procedural efficiency, patient safety, and overall healthcare costs. Studies have shown that instruments get dropped at significant rate and up to 60% of the cases. Current solutions that have shown to be effective in decreasing the rate of fall, such as magnetic drapes, have limitations, particularly with their inability to support non-metallic instruments. This thesis addresses this gap by designing, developing and evaluating a magnetic retention system that can decrease the rate of fall of nonmetallic instruments. Through an iterative process, the study developed small magnetic clips that can be mounted to non-metallic instruments and allow them to be compatible with the conventional magnetic drapes. To evaluate the new system’s effectiveness, an accelerated testing model was developed and tested in a simulated OR environment, where surgical residents were recruited to preform simulated surgical procedures using the magnetic retention system. The experimental results demonstrated a significant reduction in instrument falls when using the magnetic retention system. Without the system, the mean number of falls was 7.57 per session, while with the system, the mean number of falls dropped to 0.86 per session, p-value <0.05. Additionally, overall performance scores and task completion rates were higher when the magnetic system was used. This thesis contributes to ongoing efforts aimed to improve surgical efficiency and reducing surgical waste, by addressing the challenges associated with instrument falls in OR. The next steps include refining the magnetic retention system, and preparing for clinical trials to move toward commercialization.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Experimental Medicine
Grantor dc:publisher
University of British Columbia
Year dc:date
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mashat, Abdullah
Contributors dc:contributor
  • Mui, Alice
  • Hodgson, Antony J.

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/89228

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Mashat, Abdullah. Design and evaluation of a device to prevent instrument drops during surgery. master's thesis, University of British Columbia, 2024. http://hdl.handle.net/2429/89228