Back to search

University of British Columbia

Accuracy improvements for interior residual stress measurements

Abstract

dc:description

The accuracy of interior residual stress measurements using the layer-removal, hole-drilling and ring-core methods was enhanced in two ways. In the first way, the mathematical method for calculating residual stresses from the measured strains was made more robust by applying an inverse solution method based on Linear Inverse Theory. This approach eliminates the two main weaknesses of the existing method, stress solution sensitivity to strain measurement errors and not obeying equilibrium. Optimal smoothing is introduced as an effective method for reducing sensitivity to strain data errors. With the proposed method, stress equilibrium can be easily enforced. Both experimental and theoretical results show that the inverse solution method stabilizes the calculation procedure and it is an effective and reliable method for determining residual stresses in a material. The second way of enhancing residual stress measurement is to develop a new residual stress measurement technique. The new technique, called ring-hole drilling, overcomes the limitations of strain sensitivity to subsurface stresses of the hole-drilling and ring-core methods. By moving the strain gauges from the material surface to the interior, the overall strain sensitivity of the ring-hole drilling method is increased to double that of the ring-core method, and about four times that of the hole-drilling method. The experimental measurements made with ring-hole method correspond very closely with theoretical expectations determined using finite element method. The results show that ring-hole drilling is a practical method for evaluating residual stresses in a material.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
1998

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Liu, Xue Mei

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/9001

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Liu, Xue Mei. Accuracy improvements for interior residual stress measurements. master's thesis, University of British Columbia, 1998. http://hdl.handle.net/2429/9001