Back to search

University of British Columbia

Evaluation of the accuracy of digital workflow for implant-supported full arch fixed dental prostheses using micro-CT (novel research)

Abstract

dc:description

Objectives: This study aims to determine the accuracy of digital impressions for the fabrication of full-arch fixed prostheses by evaluating the passivity of milled titanium frameworks utilizing a novel Micro-CT measurement technique. Methods: A printed model of an edentulous mandible with implant analogues was designed using 3Shape software. Digital scanning was performed using a Trios 5 scanner, and the resulting STL file was used to design and mill ten titanium prosthesis frameworks. Baseline measurements were obtained by placing temporary cylinders on the printed model and performing a Micro-CT analysis. Micro-CT was additionally performed after placing each titanium framework on the model under two conditions: single screw test (SST-CT) and final fit test (FFT-CT). These measurements were compared to the baseline. Passivity was evaluated using single screw tests and screw resistance tests. The accuracy of the scan was assessed by superimposing the ten scans with a bench scan taken by a high-accuracy laboratory scanner (3shape E4) to determine if the lack of passivity was due to milling or scanning errors. Results: None of the frameworks (0%) were passive using Micro-CT SST. Using the Micro-CT FFT analysis, only three frameworks (30%) had an acceptable fit. The single screw test (SST) and screw resistance test (SRT) showed non-passivity rates of 60% and 80%, respectively. Superimposition analysis revealed that only two frameworks fell within the acceptable deviation range (150 µm), suggesting a high tendency for scanning errors in most frameworks and a possible milling error in two. Conclusion: The results show a significant lack of passivity in the frameworks created from digital intraoral scanning. This suggests that it may be necessary to use verification jigs in the digital workflow for full-mouth rehabilitation. Further studies are required to validate these findings with present and future intraoral scanning technologies.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Craniofacial Science
Grantor dc:publisher
University of British Columbia
Year dc:date
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Fouda, Amira
Contributors dc:contributor
  • Gebril, Mohamed

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/91408

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Fouda, Amira. Evaluation of the accuracy of digital workflow for implant-supported full arch fixed dental prostheses using micro-CT (novel research). master's thesis, University of British Columbia, 2025. http://hdl.handle.net/2429/91408