Abstract
dc:descriptionObjectives: This study aims to determine the accuracy of digital impressions for the fabrication of full-arch fixed prostheses by evaluating the passivity of milled titanium frameworks utilizing a novel Micro-CT measurement technique. Methods: A printed model of an edentulous mandible with implant analogues was designed using 3Shape software. Digital scanning was performed using a Trios 5 scanner, and the resulting STL file was used to design and mill ten titanium prosthesis frameworks. Baseline measurements were obtained by placing temporary cylinders on the printed model and performing a Micro-CT analysis. Micro-CT was additionally performed after placing each titanium framework on the model under two conditions: single screw test (SST-CT) and final fit test (FFT-CT). These measurements were compared to the baseline. Passivity was evaluated using single screw tests and screw resistance tests. The accuracy of the scan was assessed by superimposing the ten scans with a bench scan taken by a high-accuracy laboratory scanner (3shape E4) to determine if the lack of passivity was due to milling or scanning errors. Results: None of the frameworks (0%) were passive using Micro-CT SST. Using the Micro-CT FFT analysis, only three frameworks (30%) had an acceptable fit. The single screw test (SST) and screw resistance test (SRT) showed non-passivity rates of 60% and 80%, respectively. Superimposition analysis revealed that only two frameworks fell within the acceptable deviation range (150 µm), suggesting a high tendency for scanning errors in most frameworks and a possible milling error in two. Conclusion: The results show a significant lack of passivity in the frameworks created from digital intraoral scanning. This suggests that it may be necessary to use verification jigs in the digital workflow for full-mouth rehabilitation. Further studies are required to validate these findings with present and future intraoral scanning technologies.
Degree
thesis:*- Name thesis:degree_name
- Master of Science - MSc
- Level thesis:degree_level
- master's
- Discipline thesis:degree_discipline
- Craniofacial Science
- Grantor dc:publisher
- University of British Columbia
- Year dc:date
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Fouda, Amira
- Contributors dc:contributor
-
- Gebril, Mohamed
Rights
dc:rights- Statement dc:rights
-
- Attribution-NonCommercial-NoDerivatives 4.0 International
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/2429/91408