Back to search

University of British Columbia

An ex vivo multiparametric micro-ultrasound imaging system

Abstract

dc:description

Prostate cancer (PCa) is one of the most diagnosed cancers in men globally. To confirm the presence and severity of PCa, a needle biopsy procedure is performed where a series of approximately 12 core tissue samples are collected from standardized locations to obtain a histopathological diagnosis. Biopsy acquisition for PCa diagnosis is guided by ultrasound (US). While conventional US effectively delineates the external border of the prostate, it has a low sensitivity and specificity for detecting PCa. The ExactVu™ (Exact Imaging, Markham, ON, Canada) microUS system offers increased spatial resolution down to 70 microns and is non-inferior to the gold standard of PCa imaging. This thesis is split into two phases. The first focuses on increasing the ExactVu™ PCa detection accuracy through the development and implementation of an ex vivo multiparametric microUS imaging system. Shear wave elastography and strain imaging are implemented. The second phase shifts to the pathology workstation, focusing on the design and validation of a single-blade device for repeatable prostate specimen sectioning. In phase 1, a hardware system is designed and a phantom validation is carried out to evaluate cart and US probe stabilization. The phantom results indicate that the system works well. Proceeding to ex vivo data collection, a 3D-printed holder with an ellipsoidal imprint is engineered to stabilize prostate specimens. Using this holder, a proof-of-concept of mpMUS imaging is presented for two specimens. A Fourier analysis of the US transmit frequency is also completed, and is used to apply bandpass filters to the imaging results. Navigating to phase 2, a novel device design for prostate specimen sectioning is introduced. A validation study is conducted on ten specimens. Overall, a total of 80 tissue sections are acquired, with a mean centre section thickness of 3.5 ± 0.4 mm. Cutting angle drift is measured to be 1.6 ± 0.8 mm and 1.0 ± 0.7 mm, along the anterior-posterior and median-lateral axes, respectively. An ANOVA test indicate no statistically significant difference between mean centre section thicknesses, validating that the device generates sections of uniform thickness. Overall, this thesis presents two projects to improve PCa diagnosis and surgical pathology.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Desaigoudar, Vedanth
Contributors dc:contributor
  • Salcudean, Septimiu Edmund

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/91673

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Desaigoudar, Vedanth. An ex vivo multiparametric micro-ultrasound imaging system. master's thesis, University of British Columbia, 2025. http://hdl.handle.net/2429/91673