Back to search

University of British Columbia

Thermal measurements of medical isotope targets

Abstract

dc:description

Medical isotopes are used in medicine to diagnose or treat various diseases. These isotopes are used in radiopharmaceuticals that are needed to perform Positron Emission Tomography (PET) and Single-Photon Emission Computed Tomography (SPECT) scans, as well as for the treatment of cancer using Targeted Radionuclide Therapy (TRT). This thesis focuses on establishing a reliable method for temperature measurement in cyclotron medical isotope production targets using fibre Bragg gratings (FBGs). The research addresses the gap between theoretical and experimental radioisotopic yields, which partly comes from insufficient understanding of the thermal conditions within targets during irradiation. A preliminary study was performed to establish temperature bounds in solid targets using low melting-point metals. The results from these experiments established a refined helium heat transfer coefficient (875±105 W/m2K) using ANSYS thermal modelling software with energy deposition input from FLUKA, a Monte Carlo particle transport simulation package. After this process was completed, a sensitivity analysis was performed since it was noted that minor changes in target setup affected the simulated temperature distribution. The primary experiments, performed using FBG sensors in liquid (water) targets at TRIUMF’s 13 MeV cyclotron, demonstrated successful correlation between the FBG wavelengths and beam current. In early irradiations, boiling conditions were detected when the FBG wavelengths plateaued even as the beam current increased, at which point the temperature was calculated to be within ±5 °C of 100 °C. A significant finding was that the FBG sensors require a radiation annealing process (determined to be 2830 ± 30 µA·min outside the beam path and 1920 ± 20 µA·min directly in the beam path) before providing stable measurements in the radioactive environment. From these results, it can be concluded that while FBG sensors can perform temperature measurements in radioactive environments, they must undergo annealing prior to making reliable measurements. This research provides empirical data and lays the groundwork for obtaining additional data necessary for validating existing target models that presently rely on simulated input. These models are crucial for optimizing target design that will contribute to improving the efficiency of cyclotron-based radioisotope production.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Medical Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dehnel, Grace
Contributors dc:contributor
  • Jirasek, Andrew

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/91824

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Dehnel, Grace. Thermal measurements of medical isotope targets. master's thesis, University of British Columbia, 2025. http://hdl.handle.net/2429/91824