University of British Columbia
Fe(III)-Fe(II) redox kinetics and their effects on 2205 duplex stainless steel crevice corrosion
Abstract
dc:descriptionThis study investigates the electrochemical behavior of the Fe(III)/Fe(II) redox couple and its effect on the crevice corrosion resistance of 2205 duplex stainless steel (DSS) under hydrometallurgical conditions. The research is divided into two parts: redox kinetics and critical crevice temperature (CCT) evaluation. The kinetics of the Fe(III)/Fe(II) redox couple were examined in 0.5 M sulfuric acid at 25, 60 and 95 °C across Fe(III)/Fe(II) ratios of 1:10, 1:1, and 1000:1. A novel method previously applied to sulfide minerals was adapted to isolate the mixed potential for the first time on 2205 DSS. The reversible potential (Erev) was maintained within the passive region of DSS to minimize corrosion interference. Both potentiodynamic polarization (PDP) and immersion tests were conducted, showing 2205 DSS remained passive between 0–1 V vs. SHE under all tested conditions. No significant weight loss (<0.1 mm/y) or pitting was observed after 60-days of immersion at 95 °C under varying Fe(III)/Fe(II) ratios. Potentiostatic tests revealed well-defined Tafel regions with R² > 0.95. While temperature had only a slight effect on Erev at a 1:1 ratio (rising from 0.65 V to 0.68 V), the Fe(III)/Fe(II) ratio showed a strong logarithmic influence: from 0.60 V at 1:10 to 0.86 V at 1000:1. Erev always remained in the passive region, helping protect against localized corrosion. CCT testing revealed a clear inverse correlation between the Fe(III)/Fe(II) ratio and the critical crevice temperature (CCT) in the presence of chloride ions. In the absence of Fe(III)/Fe(II), the CCT decreased from 98.7 °C at 1 g/L Cl⁻ to 39.9 °C at 15 g/L. The presence of Fe(III)/Fe(II) further reduced the CCT by 10–20 °C at a 1:10 ratio, and by an additional 5–10 °C at 1:1 and 1000:1 ratios. Under the most aggressive condition—15 g/L NaCl with a 1000:1 Fe(III)/Fe(II) ratio—crevice corrosion occurred at room temperature. Elevated Fe(III) promoted anodic dissolution and passive film breakdown in crevices. Microscopy confirmed localized corrosion beneath crevice formers. OM revealed distinct crevice regions, and SEM-BSE imaging showed corrosion along α/γ phase boundaries, with ferrite (α) undergoing preferential attack due to galvanic effects.
Degree
thesis:*- Name thesis:degree_name
- Master of Applied Science - MASc
- Level thesis:degree_level
- master's
- Discipline thesis:degree_discipline
- Materials Engineering
- Grantor dc:publisher
- University of British Columbia
- Year dc:date
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Zong, Pengfei
- Contributors dc:contributor
-
- Asselin, Edouard
Rights
dc:rights- Statement dc:rights
-
- Attribution-NonCommercial-NoDerivatives 4.0 International
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/2429/92498