Back to search

University of British Columbia

Improving wearable out-of-hospital pulse oximetry estimation with novel real-time analysis of photoplethysmography

Abstract

dc:description

Cardiopulmonary emergencies and chronic cardiopulmonary illnesses remain leading causes of morbidity and mortality, largely because events occurring outside medical supervision go unwitnessed. Wearable sensing offers the possibility of detecting acute physiological decline in real-time, yet current commercial systems are constrained by limitations in sensitivity, specificity, validation, mathematical and data processing paradigms for monitoring hypoxic physiological states, and user-adherence barriers. Specifically, SpO₂ - a common indicator of arterial oxygenation - requires a pulse to provide a result, thus failing during low perfusion states or cardiac arrest. This thesis investigates whether acute desaturation can be continuously monitored using photoplethysmography (PPG)-based devices to enable rapid detection of acute cardiopulmonary instability. To address this question, three complementary aims were pursued. A pan-Canadian population survey examined user preferences and willingness to adhere to continuous wearable use for critical illness detection. Responses (n ≈ 400) revealed a strong preference for hand-based form factors and identified age- and activity-dependent differences in adherence behavior, underscoring the need for user-centered design and public education on critical illness risk. Building on these insights, the second aim advanced the analytical foundations of PPG-derived oxygen saturation (SpO₂) estimation. A derivative Beer–Lambert model was developed to infer changes in arterial oxygenation (ΔSpO₂) independent of pulsatile blood flow, introducing a calibration coefficient α that remained generalizable across participants. A multivariate Kalman filter was subsequently implemented to fuse instantaneous SpO₂ and derivative information (dDiff), yielding semi-lagless SpO₂ tracking with markedly improved temporal resolution, tested in a simulated benchtop hypoxemia experiment to establish model accuracy relative to a clinical pulse oximeter. The third aim validated these methods in experimental simulated pulselessness. This arterial-occlusion study demonstrated stability under near-pulseless conditions using a perfusion-index-weighted dynamic Kalman filter. Together, these studies produced a reproducible, open-source pipeline for algorithmic validation in simulated cardiopulmonary illness. Collectively, this work reframes wearable PPG from a passive optical signal into an active estimator of cardiopulmonary deterioration. By integrating user behavior, mathematical modeling, and physiological validation, it establishes a pathway toward real-time, device-agnostic detection of critical illness. The findings have implications for both clinical monitoring and the future of consumer-grade health technologies.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lingawi, Saud
Contributors dc:contributor
  • Kuo, Calvin

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/93329

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Lingawi, Saud. Improving wearable out-of-hospital pulse oximetry estimation with novel real-time analysis of photoplethysmography. doctoral thesis, University of British Columbia, 2025. http://hdl.handle.net/2429/93329