Back to search

University of British Columbia

Proposed protocol for internal dosimetry using patient-specific attenuation-corrected spect scans

Abstract

dc:description

The Medical Internal Radiation Dose (MIRD) protocol has provided a solid foundation over the years for calculating the internal absorbed dose but as for providing an assessment that is specific to the individual patient's organ/tumor anatomy, it falls short. Various methods have been proposed to overcome the shortcomings of the MIRD protocol, but each has its own limitations. Quantitative SPECT proves to be the most desirable option for determining dose estimates, yet the prolonged scan times prevent SPECT from becoming a clinical protocol in dosimetry. Given the time constraints of clinical SPECT, planar quantitative imaging has proved a popular choice for dosimetry studies, but the resulting dose overestimates may prevent maximum therapy from being achieved. Proposed here is a protocol that contends to be clinically feasible, patient-specific, and promising in its results. This protocol combines the benefits of both quantitative planar and SPECT imaging. By maintaining the majority of scans as planar yet incorporating the benefits of attenuation corrected SPECT scans, a more accurate, yet attainable clinical protocol can be achieved. The 2 or more SPECT scans suggested make use of a Gadolinium-153 transmission source so that a simultaneous emission/transmission scan provide a patient-specific, attenuation corrected SPECT image. The SPECT data is then used to constrain the planar data, resulting in a more accurate dose estimate than would arise from planar alone. Phantom experiments demonstrate that the errors in absorbed dose estimates have improved from an average of 159% for planar methods alone to 14% by the addition of a SPECT constraint.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
1999

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hannis, Leah

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/9395

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Hannis, Leah. Proposed protocol for internal dosimetry using patient-specific attenuation-corrected spect scans. master's thesis, University of British Columbia, 1999. http://hdl.handle.net/2429/9395