University of British Columbia
Development of an electrified penile implant with wireless control for enhanced user experience
Abstract
dc:descriptionErectile dysfunction (ED) is a pervasive condition affecting millions of men worldwide, with an increasing incidence expected over the coming years. Traditional penile implants, though effective, have seen minimal technological advancement over the past few decades, leading to limitations in natural feel, reliability, and ease of use. This thesis explores the integration of soft robotics and electrical engineering principles, particularly micropumps and electronic control systems, into the development of a next-generation penile implant. The goal of this thesis is to design, build, and bench-test a soft robotic penile implant prototype that inflates electrically under wireless smartphone control, replacing the manually squeezed scrotal pump of current devices, and to show that it can reach and hold a physiological target pressure of 100 mmHg. The research systematically evaluates the compatibility and performance of soft robotic components designed for axial and radial expansion within the penile implant. Various prototypes were developed using innovative materials and designs, including a porous structure aimed at minimizing fluid volume while maximizing expansion capacity. Additionally, the study incorporates electrical pressurization systems, calibrated through force-sensitive resistors and controlled wirelessly via a Bluetooth connection, allowing for discreet and convenient operation through a smartphone interface. Bench testing showed that the prototype reached a target pressure of 100 mmHg within 30 seconds under wireless command, removing the repeated manual actuation required by conventional pump systems. A constraining shell analogous to the tunica albuginea bounds the actuator's expansion. A closed-form hyperelastic analysis developed here shows that such a constraint is not merely cosmetic: an unconstrained elastomeric wall of these dimensions cannot sustain the physiological target pressure at any stretch, across the full plausible range of geometry and material stiffness. As a bench-scale feasibility study, carried out with non-implantable hardware and without human or animal subjects, this work establishes a control architecture that can inform the future development of implantable devices of this class.
Degree
thesis:*- Name thesis:degree_name
- Master of Applied Science - MASc
- Level thesis:degree_level
- master's
- Discipline thesis:degree_discipline
- Electrical Engineering
- Grantor dc:publisher
- University of British Columbia
- Year dc:date
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Fatemi, Parham
- Contributors dc:contributor
-
- Mohammadi, Hadi
Rights
dc:rights- Statement dc:rights
-
- Attribution-NonCommercial-NoDerivatives 4.0 International
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/2429/95879