Back to search

University of British Columbia

Development of an electrified penile implant with wireless control for enhanced user experience

Abstract

dc:description

Erectile dysfunction (ED) is a pervasive condition affecting millions of men worldwide, with an increasing incidence expected over the coming years. Traditional penile implants, though effective, have seen minimal technological advancement over the past few decades, leading to limitations in natural feel, reliability, and ease of use. This thesis explores the integration of soft robotics and electrical engineering principles, particularly micropumps and electronic control systems, into the development of a next-generation penile implant. The goal of this thesis is to design, build, and bench-test a soft robotic penile implant prototype that inflates electrically under wireless smartphone control, replacing the manually squeezed scrotal pump of current devices, and to show that it can reach and hold a physiological target pressure of 100 mmHg. The research systematically evaluates the compatibility and performance of soft robotic components designed for axial and radial expansion within the penile implant. Various prototypes were developed using innovative materials and designs, including a porous structure aimed at minimizing fluid volume while maximizing expansion capacity. Additionally, the study incorporates electrical pressurization systems, calibrated through force-sensitive resistors and controlled wirelessly via a Bluetooth connection, allowing for discreet and convenient operation through a smartphone interface. Bench testing showed that the prototype reached a target pressure of 100 mmHg within 30 seconds under wireless command, removing the repeated manual actuation required by conventional pump systems. A constraining shell analogous to the tunica albuginea bounds the actuator's expansion. A closed-form hyperelastic analysis developed here shows that such a constraint is not merely cosmetic: an unconstrained elastomeric wall of these dimensions cannot sustain the physiological target pressure at any stretch, across the full plausible range of geometry and material stiffness. As a bench-scale feasibility study, carried out with non-implantable hardware and without human or animal subjects, this work establishes a control architecture that can inform the future development of implantable devices of this class.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Electrical Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Fatemi, Parham
Contributors dc:contributor
  • Mohammadi, Hadi

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/95879

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-21
Source record
OAI-PMH GetRecord
related terms
citation

Fatemi, Parham. Development of an electrified penile implant with wireless control for enhanced user experience. master's thesis, University of British Columbia, 2026. http://hdl.handle.net/2429/95879