An investigation of the failure mechanisms of aluminum cathodes in zinc electrowinning cells

Abstract

dc:description

Aluminum cathodes have long been used for the electrowinning of zinc from zinc sulfatesulfuric acid electrolyte. Severe corrosion above the electrolyte/air interface limits the life of aluminum cathodes to ca. 18-24 months for a 6 mm thick plate. The failure characteristics of aluminum cathodes were analyzed using optical microscopy, scanning electron microscopy, energy dispersive x-ray analysis, and x-ray diffraction analysis. Three corrosion zones were identified: zone I below the electrolyte/air interface, zone II 0-40 mm above the electrolyte/air interface, and zone III 40-140 mm above the electrolyte/air interface. Zone II experienced maximum corrosion damage in the form of shallow, dense, cusp-like pitting. For a rejected aluminum plate, the corrosion damage in zone II was ca. 80% reduction in plate thickness. The corrosion damage in zones I and III was minor corresponding to ca. 10% reduction in plate thickness. The failure pattern of aluminum cathodes and the factors causing variation in corrosion rate in the different zones were studied. Corrosion processes occurring under thin electrolyte film conditions limited the life of the cathode plate. The influence of microstructure, chloride, and fluoride on the corrosion susceptibility of aluminum cathodes was investigated in simulated and industrial electrolytes using cyclic polarization, potentiodynamic polarization, potentiostatic, galvanostatic, open circuit, and free immersion techniques. These techniques were coupled with electron metallography and chemical analysis of test solutions. The corrosion rate of the aluminum cathode plate decreased with increased pH and zinc concentration. Titanium addition to the cathode plate undermined its corrosion resistance in zone I by enhancing hydrogen evolution. In the presence of cathodic polarization, fluoride activated zone I corrosion but had minimal effect on zone II corrosion. Chloride had minimal effect on zone I corrosion; however, it strongly activated zone II corrosion and was the primary factor responsible for plate failure. A mechanism through which chloride acted on the aluminum cathode plate was proposed.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Materials Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
1999

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Buarzaiga, Mohamed

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/9941

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Buarzaiga, Mohamed. An investigation of the failure mechanisms of aluminum cathodes in zinc electrowinning cells. doctoral thesis, University of British Columbia, 1999. http://hdl.handle.net/2429/9941