Back to search

Central Florida

Wirelessly Sensing Resonate Frequency Of Passive Resonators With Different Q Values

Abstract

dc:description.abstract

Numerous techniques exist for measuring temperature using passive devices such as SAW filters. However, SAW filters have a significant limitation regarding high temperature environments exceeding 1000⁰C [1]. There are several applications for a high temperature sensor in this range, most notably heat flux or temperature in turbine engines. For these environments, an alternative to SAW filters is to use a passive resonator. The resonate frequency will vary depending on the environment temperature. Understanding how the frequency changes with temperature will allow us to determine the environmental temperature. In order for this approach to work, it is necessary to induce resonance in the device and measure the resonance frequency. However, the extreme high temperature makes wired connections impractical, therefore wireless interrogation is necessary. To be practical a system of wireless interrogation of up to 20cm is desired.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lukacs, Mathew Walter

Subjects

dc:subject × 7

Rights

Language dc:language
English

Identifiers

dc:identifier.*
Identifier
CFE0003709

Chain of custody

source
Harvested from
Central Florida
Base URL
stars.library.ucf.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Lukacs, Mathew Walter. Wirelessly Sensing Resonate Frequency Of Passive Resonators With Different Q Values. https://stars.library.ucf.edu/etd/2076