Back to search

University of Central Florida

Tailoring of the Left Ventricular Assist Device Cannula Implantation Using Coupled Multi-Scale Multi-Objective Patient Specific Optimization.

Abstract

dc:description.abstract

Despite advancements in device design and anti-coagulation treatments, there are numerous adverse events that may occur following implantation of LVADs. The most devastating involves the embolization of thrombus into the brain causing a stroke, with incidence of up to 14-47% over a 6–12-month period. This study aims to elucidate ways to reduce this risk by surgical maneuvers guided by a multi-scale computational fluid dynamics analysis wrapped around a multi-objective shape optimization scheme which optimizes the anastomosis location of the VAD outflow graft (OG) along the ascending aorta to minimize the incidence of thrombi reaching the cerebral vessels and reduce particle residence times. The computational model comprises of two coupled parts: a 50 degree of freedom 0-D lumped parameter model of the peripheral circulation that is loosely-coupled to a 3-D CFD model of the aortic circulation. Blood flow is modeled as laminar, incompressible and the non-Newtonian blood rheology is accounted for by the Carreau-Yasuda model. A Lagrangian particle tracking scheme is used to model thrombi as non-interacting particles. The results verify the hypothesis that a surgical maneuver that tailors the LVAD-OG anastomosis configuration can minimize the incidence of cerebral embolization. This is exemplified most in the case that considered particle release from the OG, as a fivefold decrease in cerebral embolization resulted from optimizing the implantation configuration. It was found that shallow orientations are most optimal in minimizing the cerebral embolization in the case where particles originate from the aortic root walls and the ventricle. In the last case, where particles were released from all three origins, the optimal implantations show a proclivity for intermediate implementations that direct the momentum of the VAD-jet towards the lumen of the aortic arch. Discrete coefficient of restitution sensitivity analysis reveals a negligible effect on cerebral embolization incidence as particle-wall collisions become less elastic.

Degree

thesis:*
Grantor dc:publisher
University of Central Florida

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dankano, Abubakar
Contributors dc:contributor
  • Kassab, Alain

Subjects

dc:subject × 4

Rights

Language dc:language
English

Identifiers

dc:identifier.*
Identifier
CFE0008817; DP0026096

Chain of custody

source
Harvested from
Central Florida
Base URL
stars.library.ucf.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Dankano, Abubakar. Tailoring of the Left Ventricular Assist Device Cannula Implantation Using Coupled Multi-Scale Multi-Objective Patient Specific Optimization.. University of Central Florida, https://stars.library.ucf.edu/etd2020/846