Back to search

University of Central Florida

Measurement of Transient Coherent Effects in IR/THz Double Resonance Spectroscopy in the Low-Pressure Regime

Abstract

dc:description.abstract

There is demonstrated need for the capability to detect spectral signatures of trace gases at atmospheric pressure. While many remote sensing techniques are effective, they suffer limitations in their ability to discriminate trace gases at high pressures. This stems from the broadening of spectral lines washing away the spectral fingerprint as pressure increases. A double-resonance (DR) infrared (IR)/Terahertz (THz) ro-vibrational spectroscopy solution is proposed. The ability to discriminate between molecules or specific isotopic isomers of the same molecule using this double-resonance spectroscopy (DRS) technique comes from the unique pump source coincidence with the spectral lines of the trace gas and the probing of the transient changes in absorption seen in neighboring rotational transitions. These pump/probe combinations are unique to each isotopic isomer. In order to predict the behavior of this technique at atmospheric pressures, it must first be understood in the low-pressure regime. A set of experiments were conducted using a pulsed carbon dioxide (CO2) long-wave infrared (LWIR) laser pump source and THz probe source. The trace gas interrogated was methyl chloride 35 (CH335Cl) and the diluting gas was nitrogen (N2). Hyperfine frequency contributions were measured, and transient coherent behavior was observed. A model was also developed to simulate the coherent behavior at low-pressures and predict what is expected in the atmospheric regime. Experimental methods and results are discussed along with model output and predictions and a path toward atmospheric DRS experiments is detailed.

Degree

thesis:*
Grantor dc:publisher
University of Central Florida

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Schneiderman, Max
Contributors dc:contributor
  • Richardson, Martin

Subjects

dc:subject × 3

Rights

Language dc:language
English

Identifiers

dc:identifier.*
Identifier
CFE0009408; DP0027131

Chain of custody

source
Harvested from
Central Florida
Base URL
stars.library.ucf.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Schneiderman, Max. Measurement of Transient Coherent Effects in IR/THz Double Resonance Spectroscopy in the Low-Pressure Regime. University of Central Florida, https://stars.library.ucf.edu/etd2020/1437