Back to search
University of Central Florida
Evolution of a Cooling Water Treatment Program at a Chemical Processing Plant
Abstract
dc:description.abstractDuring the construction of a chemical processing plant, a polyphosphate product was selected for use as a corrosion inhibitor in the open recirculating cooling tower system. After several months of operation, problems in the system made evident the fact that polyphosphate as a corrosion inhibitor was not acceptable. An organic corrosion inhibitor was substituted for the phosphate, resulting in improved corrosion protection and the elimination of phosphate fouling.
Degree
thesis:*- Grantor dc:publisher
- University of Central Florida
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Everson, Lawrence P.
- Contributors dc:contributor
-
- Clausen, Chris A.
- <p><a href="https://viaf.org/viaf/263560708">Clausen, Chris A., 1940-</a> [VIAF]</p> <p><a href="http://id.loc.gov/authorities/names/n78032138">Clausen, Chris A., 1940-</a> [LC]</p>
Subjects
dc:subject × 9- Corrosion and anti corrosives
- Water purification
- Polyphosphate corrosion inhibitors
- Organic inhibitor replacement
- Open recirculating cooling water systems
- Phosphate scaling and fouling
- Corrosion control program evolution
- Chemistry
- Corrosion and anti corrosives; Water -- Purification; Cooling towers--Corrosion; Chemical plants--Equipment and supplies--Corrosion; Corrosion and anti-corrosives--Prevention; Fouling--Prevention; Corrosion and anti-corrosives
Rights
dc:rights- Statement dc:rights
-
- Public Domain
- Language dc:language
- English
Identifiers
dc:identifier.*- Identifier
- DP0013345