Back to search

University of Central Florida

Chemical and mechanical analysis on CMP polyurethane pads

Abstract

dc:description.abstract

Chemical Mechanical Polishing (CMP) is a critical process for integrated circuit (IC) fabrication. Polishing pads play an important role in chemical mechanical polishing which has recently been recognized as the most effective method to achieve global planarization in very large-scale integrated circuit multi-level interconnects. In one model, the polishing process involves intimate contact between high points on the wafer surface and the pad material in the presence of slurry. In this study, structural, chemical and mechanical property changes of polyurethane polishing pad during CMP were studied. The polyurethane pads analyzed were a laminate structure consisting of an IC lOOO and a Suba IV pad which were pre-stacked. The top IClOOO layer contains randomly distributed pores, or voids. The CMP polishing removal rate is sensitive to pad surface structure and chemistry. White light interferometer (WLI) was used to understand the roughness of pad surface. A surface-sensitive chemical technique - Attenuated Total Reflectance Fourier Transform Infrared (ATR/Ff-IR) spectroscopy was used for the nondestructive analysis of the polymer pads. Chemical and structural changes to the pad surface were seen after polishing, though changes were restricted only to surface not in the bulk of pads. In order to understand the structural and mechanical behaviors of new (unused) and spent (end of use) pads, various thermal techniques were employed. Dynamic mechanical analysis (DMA), differential scanning calorimetry (DSC) and thermo­gravimetric analysis (TGA) were used to qualitatively and quantitatively probe pad structural modifications with use. These thermal and dynamic studies show that the mechanical behavior of polyurethane pads was modified after CMP process. In contrast, it was found that the chemical modification reacting with use has less effect on the structural of pad materials. This thesis presents comprehensive interpretation that the mechanical factors rather than the chemical factors have the largest impact on modifying pad's elastic property and accelerating the degradation. Using this information, pads that minimize the need for conditioning would be highly desirable, since the improvement in pad life and tool throughput would significantly reduce process cost.

Degree

thesis:*
Grantor dc:publisher
University of Central Florida

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lu, Huijun
Contributors dc:contributor
  • Richardson, Kathleen

Subjects

dc:subject × 12

Rights

Language dc:language
English

Identifiers

dc:identifier.*
Identifier
DP0028718

Chain of custody

source
Harvested from
Central Florida
Base URL
stars.library.ucf.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Lu, Huijun. Chemical and mechanical analysis on CMP polyurethane pads. University of Central Florida, https://stars.library.ucf.edu/rtd/1264