University of Central Florida
A Piezoelectric Actuated Scanning Mirror System Utilizing a Type One Control Loop
Abstract
dc:description.abstractThe purpose of this thesis is to design and build an improved control loop for a piezoelectric actuated scanning mirror system. A control system has been built having zero steady state position error and an 80 Hertz bandwidth. This was achieved by placing the piezoelectric actuator in the feedback path of an operational amplifier and placing series cascaded notch filters and lead compensators in the forward path of the control loop. A prototype system, including compensation and feedback, is developed. Its performance compares favorably with that of the system model. It is capable of plus and minus 1.7 degrees of angular deflection.
Degree
thesis:*- Grantor dc:publisher
- University of Central Florida
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Gibbs, David
- Contributors dc:contributor
-
- Harris, Michael
Subjects
dc:subject × 9- Type I control loop
- Cascaded notch filters
- Lead compensators
- Piezoelectric actuator feedback configuration
- 80 Hz bandwidth ±1.7° angular deflection
- Electrical and Computer Engineering
- Engineering
- Systems and Communications
- Dissertations; Academic -- Engineering; Engineering -- Dissertations; Academic; Feedback control systems--Design and construction; Piezoelectric devices--Design and construction; Servomechanisms--Design and construction; Feedback control systems--Technique; Optical instruments--Automatic control
Rights
dc:rights- Statement dc:rights
-
- Public Domain
- Language dc:language
- English
Identifiers
dc:identifier.*- Identifier
- DP0022061