A Piezoelectric Actuated Scanning Mirror System Utilizing a Type One Control Loop

Abstract

dc:description.abstract

The purpose of this thesis is to design and build an improved control loop for a piezoelectric actuated scanning mirror system. A control system has been built having zero steady state position error and an 80 Hertz bandwidth. This was achieved by placing the piezoelectric actuator in the feedback path of an operational amplifier and placing series cascaded notch filters and lead compensators in the forward path of the control loop. A prototype system, including compensation and feedback, is developed. Its performance compares favorably with that of the system model. It is capable of plus and minus 1.7 degrees of angular deflection.

Degree

thesis:*
Grantor dc:publisher
University of Central Florida

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gibbs, David
Contributors dc:contributor
  • Harris, Michael

Subjects

dc:subject × 9

Rights

dc:rights
Statement dc:rights
  • Public Domain
Language dc:language
English

Identifiers

dc:identifier.*
Identifier
DP0022061

Chain of custody

source
Harvested from
Central Florida
Base URL
stars.library.ucf.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation